    A hotel corridor carpet cleaned at night is still damp and musty two days later, and then dulls faster than before. This chapter covers water-based carpet and upholstery cleaners, starting from the manufacturer’s safety data sheet for one product in this group: a ready-to-use liquid at pH 9.2 with two glycols at a few percent each and an eye irritation classification. It covers how surfactants and glycols work, what pH 9.2 means for fibers and dyes, the colorfastness test in a hidden spot, the liquid balance in the extraction and foam methods, the residue left behind and resoiling, drying against the 24-hour and 72-hour limits from United States guidance, the threshold limit values for the two glycols under Permenaker 5/2018, first aid, and handling and storage. Dosage and method of use still follow the product label; moldy carpet, upholstery contaminated with body fluids, and water-sensitive textiles are stated to be work for other parties.

    Section you’re reading: Chapter opening

    The third-floor corridor carpet of a hotel was cleaned on a Thursday night, after that wing had been cleared of guests. The attendant filled the machine tank with a ready-to-use carpet cleaner, sprayed the center lane twice because it looked dull, and then vacuumed it up once. The air conditioning in that wing was switched off all night. On Saturday morning guests complained that the carpet was still damp and smelled musty, and two weeks later that center lane was duller than before it was cleaned.

    The product was not at fault and the machine was not broken. The manufacturer’s safety data sheet for one product in this group describes a ready-to-use liquid at pH 9.2, with two glycols at a few percent each and one hazard class, namely eye irritation. The complaint came from a balance nobody calculated: how much liquid went into the carpet, how much came back to the recovery tank, what stayed on the fibers, and where the water vapor went.

    Scope

    This chapter covers water-based carpet and upholstery cleaners: what the product contains, what its pH means, the colorfastness test, the extraction and foam methods, the residue left behind, drying, worker exposure, and handling and storage. The product data come from the manufacturer’s safety data sheet for one product in this group; other products may differ, so the label and the safety data sheet of the product actually in use remain the reference. This chapter is study material, not a work instruction. Dosage, contact time, and method of use are not given here, because only the product label has the authority to give them.

    How to check a safety data sheet is covered in Chapter 26 on reading the safety data sheet of a cleaning product, and SDSs in general in Chapter 10 on SDSs and functional classes. Surfactants and foam are covered in Chapter 21 on surfactants, colloids, and emulsions, pH in Chapter 15 on advanced acids and bases, fibers in Chapter 2 · Laundry on textiles for laundry, and stains in Chapter 13 · Laundry on stain treatment. Labels and spills are in Chapter 6 · Safety on chemicals in technician work, and hazardous mixtures in Chapter 25 on chemical reactivity and incompatibility. All-purpose cleaners for hard surfaces are covered in Chapter 27 and Chapter 28.

    Outside the authority of cleaning staff and building technicians: carpet or upholstery contaminated with blood or body fluids in patient-care areas, carpet that is moldy or flooded, wool and silk rugs and upholstery whose care label forbids water, and large spills. That work belongs to the hospital infection prevention and control team, a water damage restoration contractor, a specialist textile care service, and trained spill responders.

    What is in the bottle: water, surfactant, and two glycols

    According to the manufacturer’s safety data sheet for one product in this group, the product is a liquid and is sold ready to use. Its relative density is 1.013, so one liter of product is only about 13 grams heavier than one liter of water. Its composition table names just two ingredients, both of them glycols:

    IngredientCAS numberConcentration
    Hexylene glycol (2-methyl-2,4-pentanediol)107-41-51 to 2%
    Dipropylene glycol methyl ether34590-94-81 to 3%

    The two glycols add up to 2 to 5%. The rest, 95% or more, is water and other ingredients not itemized in the table. The type of surfactant is not stated, so this chapter does not guess it.

    A surfactant is a substance whose molecule has one nonpolar hydrocarbon end and one end that is attracted to water. The nonpolar end dissolves in, or is attracted to, oil, grease, and dirt particles, while the other end is attracted to water. The molecule becomes a bridge between dirt and water, so the dirt is suspended as colloidal particles and is readily carried away by rinsing. On carpet, dirt that has been lifted is truly gone only when the liquid carrying it is vacuumed out.

    A glycol is an organic compound with two hydroxyl groups, and a glycol ether is a derivative of one that has an ether linkage. The formula of hexylene glycol contains two hydroxyl groups, while dipropylene glycol methyl ether contains two ether linkages and one hydroxyl group. The oxygen-bearing part likes water and the carbon skeleton likes oil, so both can act as cosolvents for oily soil. The safety data sheet does not explain the role of each ingredient.

    Properties of the two glycols as pure substances, according to data from NIOSH in the United States:

    Property of the pure substanceHexylene glycolDipropylene glycol methyl ether
    Solubility in watermisciblemiscible
    Boiling point388 °F, that is, 198 °C408 °F, that is, 209 °C
    Vapor pressure0.05 mmHg0.5 mmHg
    Incompatible withstrong oxidizers and strong acidsstrong oxidizers
    Notehygroscopic, absorbs moisture from the airnone

    These figures apply to the pure substances, not to a product that contains only a few percent of them.

    pH 9.2: a weak base, but still a base

    The safety data sheet records pH 9.2 for the undiluted product. The relationship between pH and hydroxide ion concentration in a dilute solution at 25 °C is

    pOH=14−pH,[OH−]=10−pOH\mathrm{pOH} = 14 - \mathrm{pH}, \qquad [\mathrm{OH^-}] = 10^{-\mathrm{pOH}}

    with [OH−][\mathrm{OH^-}] in moles per liter. For pH 9.2 this gives pOH 4.8 and a hydroxide ion concentration of about 1.6×10−51.6 \times 10^{-5} mol/L. That is 158 times the concentration in neutral water, but 631 times lower than in a pH 12 cleaner. The alkali reserve cannot be read from pH and is covered in Chapter 15 on advanced acids and bases.

    For carpet, what pH 9.2 means depends on the fiber and its dyes. Wool and silk are protein fibers that are sensitive to alkali, alkaline conditions combined with mechanical action trigger the felting of wool, and the bond between dye and fiber can weaken at high pH. All of this is explained in Chapter 2 · Laundry on textiles for laundry. So pH 9.2 does not exempt wool carpet or deeply colored upholstery from being tested first.

    The safety data sheet also lists acids as a material incompatible with this product. That entry is consistent with its pH and with the hexylene glycol data in the table above. Acidic spot removers are not used together with this product.

    The colorfastness test before wetting

    The colorfastness test is a check in a hidden spot to see whether dye transfers when the fabric is wetted with the liquid that will be used. Guidance from the United States National Park Service for flood-damaged textiles gives the simplest form: a cotton swab is wetted with a soapy-water mixture, run over the fabric, and then checked to see whether dye has transferred to the swab. Textiles with bleeding dyes are recommended for treatment by a preservation professional.

    For carpet and upholstery in a building, the liquid is replaced by the cleaner that will be used. The test spot is chosen where it cannot be seen, for example behind a seat cushion. Every color in the pattern is tested, and the absorbent cloth is white so that even the slightest color transfer shows. The waiting time follows the instructions on the label or from the carpet manufacturer.

    This test answers only whether color transfers with that liquid. The result does not apply to other liquids and does not predict shrinkage. The same guidance notes that wet textiles become about 50% heavier than when dry, so a loose rug that is wet is lifted with support, not pulled by its corner.

    The carpet manufacturer’s maintenance recommendations are also read first, as the United States EPA guidance on school air quality asks. For hospitals, the CDC guideline asks that soiled upholstered furniture in a patient’s room be moved to a maintenance area and cleaned with a process appropriate for the type of upholstery and the nature of the soil.

    The extraction method and the foam method

    Wet extraction is a way of cleaning carpet by putting cleaning liquid into the carpet pile and then drawing it back out together with the dirt using a wet vacuum. The EPA guidance names two jobs that complement each other: regular vacuuming with a well-filtered vacuum cleaner, and periodic wet extraction. Dry vacuuming first removes sand and dust before the liquid turns them into mud inside the carpet pile.

    In the foam method (shampooing), the cleaner is made into foam and brushed onto the surface of the carpet or upholstery. Foam is gas dispersed in a liquid, as covered in Chapter 21 on surfactants, colloids, and emulsions, so it carries less water than the same volume of plain liquid. Its weakness is that dirt and surfactant that are not vacuumed out stay on the fibers.

    The CDC guideline for health-care facilities adds another side. Vacuuming, shampooing, and wet cleaning with equipment can all disperse microorganisms into the air. Some carpet-cleaning formulations, if used improperly, can be dispersed into the air as a fine dust that irritates the respiratory tract. Extraction equipment that is not maintained can become a reservoir for waterborne bacteria and transfer them to the carpet. The CDC therefore asks for a method that produces few aerosols and leaves little or no residue, and for equipment that is maintained and allowed to dry between uses.

    Whatever the method, the mass of liquid left in the carpet is

    mleft=ρ Vused (1−η)m_{\text{left}} = \rho \, V_{\text{used}} \, (1 - \eta)

    with ρ\rho the density of the liquid in kg/L, VusedV_{\text{used}} the volume of liquid the machine dispenses in liters, and η\eta the fraction of the liquid that returns to the recovery tank, from 0 to 1. The contents of the recovery tank also include dirt, so an η\eta calculated from the tank tends to be slightly too high. The safety data sheet states that the product is sold ready to use, so no dilution is calculated here.

    Sticky residue and resoiling

    Resoiling is the condition in which freshly cleaned carpet gets dirty again faster than before, because cleaner residue on the fibers holds new dirt. While the surfactant is in water that is then vacuumed out, its nonpolar end lifts dirt. When the surfactant stays on the fibers after the water has evaporated, the same property holds dirt from shoe soles.

    Water leaves by evaporation, while ingredients that evaporate with difficulty stay. According to the property table above, the two glycols boil only at around 200 °C and have low vapor pressures, so they leave the fibers far more slowly than water. Hexylene glycol, being hygroscopic, can keep that residue feeling damp. The mass of that residue can be estimated with

    mresidue=w mleftm_{\text{residue}} = w \, m_{\text{left}}

    with ww the mass fraction of slow-evaporating ingredients in the liquid. From the safety data sheet only the glycol content is known, namely 2 to 5%. The content of surfactant and other ingredients is not recorded, so an estimate using the glycol figure is a lower bound for the whole residue.

    Signs of built-up residue: traffic lanes dull again quickly, the fibers feel stiff or sticky, and the carpet foams when wetted with clean water alone. The liquid balance points to two ways out: reducing what goes in, that is, using as much liquid as the label asks and no more, or increasing what comes out, that is, vacuuming again. Rinsing with clean water that is then vacuumed out dilutes that residue, and is done when the product label and the carpet manufacturer permit it.

    Drying: the 24-hour and 72-hour limits

    The liquid left behind has to evaporate into the room air, and during that time the carpet is a place for growth. The CDC guideline states that soiled carpeting that remains damp or wet is an ideal setting for gram-negative bacteria and fungi. Wet carpeting is dried thoroughly, and carpeting that is still wet after 72 hours is replaced. The EPA school guidance is stricter: carpet saturated by a spill is extracted and confirmed dry within 24 hours. Both are United States data from different settings. This chapter uses 24 hours as the working target and 72 hours as the limit at which the decision passes to management.

    Drying time can be estimated with

    t=mwaterm˙t = \frac{m_{\text{water}}}{\dot{m}}

    with mwaterm_{\text{water}} the mass of water left behind in kilograms and m˙\dot{m} the average evaporation rate in kg/h. That rate depends on air movement, temperature, and the relative humidity of the room. Carpet that is nearly dry evaporates more slowly, so this estimate is the shortest possible time.

    Water vapor from the carpet becomes a load on the air conditioning or the dehumidifier, whose capacity is calculated in Chapter 25 · Fluids & Thermal on room humidity control. In a corridor where the air conditioning is switched off, the air grows more humid and evaporation slows, as in the opening case. The cleaning schedule is therefore drawn up together with the air-conditioning technician: the air conditioning stays on, drying fans are set up, and the area is closed until it is dry.

    Dry at the surface does not yet mean dry at the carpet backing. For water-damaged materials, the CDC uses a moisture meter: absorbent materials such as carpeting and upholstered furniture that cannot be cleaned and dried within 72 hours, for example to a moisture content of 20% or less, are removed. Mold that has already grown is dealt with according to Chapter 9 · Biology & Microbiology on mold in buildings and linen, not with carpet cleaner.

    Worker exposure, personal protective equipment, and first aid

    The only hazard class written in this product’s safety data sheet is eye irritation Category 2A. The HSE in Great Britain reminds cleaners that hands that are wet for a long time or frequently can develop dermatitis, and that some ingredients in cleaning products can cause skin allergies and asthma. The controls are work techniques that avoid contact, gloves, aprons, and eye protection for some tasks, hand care, and good ventilation.

    The NIOSH data for the pure substances give more specific reasons. Hexylene glycol is recorded as irritating the eyes, skin, and respiratory system and as able to cause dermatitis and skin sensitization, and NIOSH asks that skin and eye contact be prevented. Dipropylene glycol methyl ether is recorded as irritating the eyes, nose, and throat, causing dizziness and headache, and able to enter through the skin. Waterproof gloves and eye protection when pouring and spraying are therefore reasonable; the choice is covered in Chapter 41 · Biology & Microbiology on the skin and chemicals.

    Permenaker 5/2018 (Minister of Manpower Regulation), which as of November 2026 has the status in force according to JDIH Kemnaker, sets an airborne threshold limit value (Indonesian nilai ambang batas, NAB) for dipropylene glycol methyl ether of 100 BDS or 606 mg/m³ and a permitted short-term exposure (Indonesian pajanan singkat diperkenankan, PSD) of 150 BDS or 909 mg/m³, with a skin notation. For hexylene glycol the regulation sets a ceiling concentration of 25 BDS or 121 mg/m³. BDS stands for bagian dalam sejuta, parts per million. The threshold limit value is an average concentration for work of no more than 8 hours a day or 40 hours a week, the short-term exposure applies to exposures of no more than 15 minutes, and the ceiling concentration must not be exceeded even for an instant.

    Those figures are limits for vapor in the air, not concentrations in the bottle, and measuring them is the work of an industrial hygienist. For staff, they mean that closed rooms are ventilated and that complaints of dizziness or irritation are reported.

    The first aid below follows the NIOSH procedures for the two pure substances, a cautious choice for a more dilute product.

    • Eyes. Immediately wash the eyes with large amounts of water, occasionally lifting the lower and upper lids, then get medical attention immediately.
    • Skin. Immediately wash the affected skin with water. If the liquid penetrates the clothing, immediately remove that clothing and wash the skin. If symptoms occur afterward, get medical attention immediately.
    • Breathed in large amounts. Move the person to fresh air at once. If breathing has stopped, a trained first aider gives artificial respiration and the emergency services are called. Keep the person warm and at rest, and get medical attention as soon as possible.
    • Swallowed. Get medical attention immediately.

    Beyond those steps, call the emergency services or a doctor and take the product label and safety data sheet along.

    Handling and storage

    The safety data sheet sets a storage temperature of 0 °C to 40 °C and lists acids as an incompatible material. A hot storeroom can exceed 40 °C, so the shelf temperature is measured. Containers are kept closed and labeled. Liquid in a spray bottle carries the same label and is never transferred into a used drink bottle, as covered in Chapter 6 · Safety on chemicals in technician work.

    The NIOSH data in the property table above add strong oxidizers as a material incompatible with both glycols. Carpet cleaner is therefore not stored on the same shelf as acid cleaners, chlorine bleach, and peroxide bleach, and is not mixed with any other product. The broader prohibition still applies in the same storeroom: never mix acids or ammonia with chlorine bleach, because that mixture releases toxic gas, as explained in Chapter 25 on chemical reactivity and incompatibility.

    The safety data sheet used in this chapter was issued on February 10, 2025 and expires on February 9, 2028, so its validity period is three years. A safety data sheet that has expired or does not match the product on the shelf is replaced through the supplier.

    The machine’s solution tank and recovery tank are emptied, rinsed, and allowed to dry between uses, in line with the CDC advice above. Dirty water from extraction is disposed of according to the facility’s procedure; waste classification is covered in Chapter 35 · Water & Water Treatment on hazardous waste (B3). A small spill makes a hard floor slippery and is absorbed right away, while a large spill is handled by trained responders.

    Worked example

    The figures in the examples below are practice figures, unless their origin is stated, and so are the events in the opening case. The volume per square meter, the fraction recovered, and the evaporation rate here are not dosages; dosage follows the product label and the machine manual.

    Example 1: hydroxide ion at pH 9.2. With pH 9.2 from the safety data sheet, pOH=14−9.2=4.8\mathrm{pOH} = 14 - 9.2 = 4.8 and [OH−]=10−4.8=1.6×10−5[\mathrm{OH^-}] = 10^{-4.8} = 1.6 \times 10^{-5} mol/L. Relative to neutral water the ratio is 109.2−7=102.2=15810^{9.2 - 7} = 10^{2.2} = 158 times. A pH 12 cleaner has 1012−9.2=102.8=63110^{12 - 9.2} = 10^{2.8} = 631 times the concentration at pH 9.2.

    Example 2: the mass of one jerry can and the glycol in it. The jerry can holds 20 L. With the relative density of 1.013 from the safety data sheet, its mass is 20×1.013=20.2620 \times 1.013 = 20.26 kg. The lowest glycol content is 1+1=2%1 + 1 = 2\% and the highest 2+3=5%2 + 3 = 5\%, so the glycol in the jerry can is between 0.02×20.26=0.410.02 \times 20.26 = 0.41 kg and 0.05×20.26=1.010.05 \times 20.26 = 1.01 kg.

    Example 3: liquid left in the corridor. The corridor measures 2 m by 60 m, so its area is 2×60=1202 \times 60 = 120 m². The machine dispenses 0.4 L of liquid per square meter, so Vused=0.4×120=48V_{\text{used}} = 0.4 \times 120 = 48 L. The recovery tank collects 36 L, so η=36/48=0.75\eta = 36/48 = 0.75. The liquid left behind is 48−36=1248 - 36 = 12 L, with a mass of mleft=1.013×48×(1−0.75)=12.2m_{\text{left}} = 1.013 \times 48 \times (1 - 0.75) = 12.2 kg, or about 12.2/120=0.1012.2/120 = 0.10 kg per square meter.

    Example 4: glycol residue and the effect of one rinse. From Example 3, the liquid left behind is 0.10 kg, or 100 g, per square meter. With a glycol content of 2 to 5%, the glycol residue is 0.02×100=20.02 \times 100 = 2 g to 0.05×100=50.05 \times 100 = 5 g per square meter. If the carpet is rinsed with clean water, vacuumed with the same fraction recovered, and that residue mixes evenly with the rinse water, what stays is 1−0.75=0.251 - 0.75 = 0.25 of it: 0.25×2=0.50.25 \times 2 = 0.5 g to 0.25×5=1.250.25 \times 5 = 1.25 g per square meter. Mixing inside the carpet pile is not even, so the real result is worse.

    Example 5: drying time and the 24-hour limit. The water left in the corridor of Example 3 is about 12 kg. With the air conditioning off and an average evaporation rate of 0.2 kg/h, t=12/0.2=60t = 12/0.2 = 60 hours. That exceeds the 24-hour target. With the air conditioning on and drying fans, an average rate of 0.8 kg/h gives t=12/0.8=15t = 12/0.8 = 15 hours. To be dry within 24 hours, the average rate is at least 12/24=0.512/24 = 0.5 kg/h.

    Example 6: matching BDS with mg/m³. The molar volume of an ideal gas at 25 °C and 1 atm is Vm=RT/p=8.314×298.15/101,325=0.02446V_m = RT/p = 8.314 \times 298.15 / 101{,}325 = 0.02446 m³/mol, that is, 24.46 L/mol. The mass concentration is C=xM/VmC = xM/V_m, with xx in BDS and MM the molar mass in g/mol. For dipropylene glycol methyl ether with M=148.2M = 148.2 g/mol from the NIOSH data, C=100×148.2/24.46=606C = 100 \times 148.2 / 24.46 = 606 mg/m³ and 150×148.2/24.46=909150 \times 148.2 / 24.46 = 909 mg/m³. For hexylene glycol with the molecular weight of 118.17 from the regulation, C=25×118.17/24.46=121C = 25 \times 118.17 / 24.46 = 121 mg/m³. All three figures match Permenaker 5/2018.

    Stop conditions

    1. The colorfastness test transfers color to the white cloth, or the fiber is not identified: do not wet it, then hand the decision to the housekeeping supervisor and a specialist textile care service.
    2. A container without a label, or a safety data sheet that has expired or does not match the product: do not use it, set it aside, and ask the supervisor and the supplier to confirm the contents.
    3. The product has been mixed with an acid cleaner, bleach, or another product, or the container is leaking and bulging: do not open it and do not mix it any further, keep people away, and call the occupational safety and health (K3) officer and the supplier.
    4. Liquid gets in the eyes: stop work, wash immediately with large amounts of water, and take the person to a doctor or the emergency department.
    5. A worker is dizzy, has a headache, is short of breath, or has irritation of the nose, throat, or skin: stop work, move to fresh air, report to the supervisor and the company doctor, and ask the air-conditioning technician to check the ventilation.
    6. The carpet is still wet after 24 hours or smells musty: stop wet cleaning and ask the building technician to set up dryers. Carpet that is still wet after 72 hours or is moldy is handed over to building management and a water damage restoration contractor.
    7. Carpet or upholstery is contaminated with blood or body fluids, or is in a patient-care area vulnerable to infection: only the hospital infection prevention and control team decides the method and the materials.
    8. Water gets into a floor outlet, or the machine cable is damaged: stop the machine and hand over to an electrician.
    9. A spill of one full container or more: keep people away and call trained spill responders.

    Common misinterpretations

    Guess what’s wrong first, then open the explanation.

    Common misconception

    The more liquid and foam, the cleaner.

    Why is it wrong?

    Excess liquid adds water that has to be dried and residue that holds new dirt.

    Common misconception

    pH 9.2 is almost neutral, so it is safe for all carpet.

    Why is it wrong?

    Its hydroxide ion concentration is 158 times that of neutral water. Wool, silk, and certain dyes are sensitive to alkaline conditions, so the test in a hidden spot is still done.

    Common misconception

    The safety data sheet only mentions eye irritation, so gloves are not needed.

    Why is it wrong?

    Prolonged wet work can cause dermatitis, and one of its glycols is recorded as able to cause skin sensitization as a pure substance.

    Common misconception

    Stubborn stains are dealt with by adding bleach or an acid cleaner to the tank.

    Why is it wrong?

    This product is incompatible with acids and strong oxidizers. Stains that do not come out are handled according to Chapter 13 · Laundry on stain treatment.

    Chapter 26 on reading the safety data sheet of a cleaning product gives the way to check the safety data sheet used here. Drying continues in Chapter 25 · Fluids & Thermal on room humidity control, disinfectants are covered in Chapter 4 · Biology & Microbiology, and hard floors at the carpet edge that also get wet in Chapter 39 · Buildings & Facilities on floors and tiles.

    Exercises and worked solutions

    The numbers in the exercises are for practice.

    Try to answer first, then open the worked solution.

    1. How many times higher is the hydroxide ion concentration of a pH 11 cleaner than that of a carpet cleaner at pH 9.2?

      Check my answer
      See the worked solution

      The ratio is 1011−9.2=101.8=6310^{11 - 9.2} = 10^{1.8} = 63 times. A pH 11 cleaner must therefore not be treated as equivalent for alkali-sensitive fibers.

    2. A container holds 5 L of carpet cleaner with a relative density of 1.013 and a glycol content of 2 to 5%. What is the mass of its contents and the range of the glycol mass?

      Check my answer
      See the worked solution

      Its mass is 5×1.013=5.0655 \times 1.013 = 5.065 kg. The glycol is between 0.02×5.065=0.100.02 \times 5.065 = 0.10 kg and 0.05×5.065=0.250.05 \times 5.065 = 0.25 kg.

    3. A carpeted meeting room measuring 8 m by 12 m is cleaned with 0.5 L of liquid per square meter, and the recovery tank collects 33.6 L. What fraction is recovered and how many liters are left per square meter?

      Check my answer
      See the worked solution

      The area is 8×12=968 \times 12 = 96 m² and the liquid used is 0.5×96=480.5 \times 96 = 48 L. The fraction recovered is 33.6/48=0.7033.6/48 = 0.70, so what is left is 48−33.6=14.448 - 33.6 = 14.4 L, or 14.4/96=0.1514.4/96 = 0.15 L per square meter.

    4. The water left in the meeting room of Exercise 3 is about 14.4 kg and the average evaporation rate is 0.5 kg/h. Is the 24-hour target met, and what is the minimum rate required?

      Check my answer
      See the worked solution

      The drying time is 14.4/0.5=28.814.4/0.5 = 28.8 hours, so the 24-hour target is not met. The minimum rate is 14.4/24=0.614.4/24 = 0.6 kg/h, and because evaporation slows toward the end of drying, the initial rate needs to be above that figure.

    5. The white cotton in the colorfastness test on a rug turns reddish. What is done, and why?

      Check my answer
      See the worked solution

      Wet cleaning is not carried out, because the dye has been shown to transfer with that liquid. The rug is handed over to a specialist textile care service.

    6. Why is this carpet cleaner not stored on the same shelf as acid bathroom cleaner and bleach?

      Check my answer
      See the worked solution

      The safety data sheet lists acids as an incompatible material, and the data on its glycols add strong oxidizers such as bleach. Separate storage also keeps the contents of leaking containers from mixing, including acid with chlorine bleach, which releases toxic gas.

    References

    External sources

    • Chemistry 2eopenstax.org
    • NIOSH Pocket Guide to Chemical Hazards: Hexylene glycolcdc.gov
    • NIOSH Pocket Guide to Chemical Hazards: Dipropylene glycol methyl ethercdc.gov
    • Preservation Matters: Disasters - Saving Wet Textiles After a Floodnps.gov
    • Controlling Pollutants and Sources: Indoor Air Quality Design Tools for Schoolsepa.gov
    • Guidelines for Environmental Infection Control in Health-Care Facilitiescdc.gov
    • COSHH and cleaners - key messageshse.gov.uk
    • Peraturan Menteri Ketenagakerjaan Nomor 5 Tahun 2018 tentang Keselamatan dan Kesehatan Kerja Lingkungan Kerjajdih.kemnaker.go.id
    • First Aid Procedures for Chemical Hazardscdc.gov

    Revision history

    DateVersionChange
    November 15, 20261First published

    How to cite

    Kurnia (2026). Carpet and upholstery cleaners: surfactants and glycols, pH, colorfastness testing, extraction and foam methods, sticky residue and resoiling, drying, and handling and storage. ARSTEMA Academy. Revised November 15, 2026. arstema.com/en/academy/konsep/pembersih-karpet-dan-kain-pelapis-surfaktan-dan-glikol-ph-uji-ketahanan-warna-cara-ekstraksi-dan-busa-sisa-lengket-dan-pengotoran-ulang-pengeringan-serta-penanganan-dan-penyimpanan

    Self-check · 3 questions

    Check your understanding before moving on

    Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.

    0/3rated
    1

    How many times higher is the hydroxide ion concentration of a pH 11 cleaner than that of a carpet cleaner at pH 9.2?

    2

    A container holds 5 L of carpet cleaner with a relative density of 1.013 and a glycol content of 2 to 5%. What is the mass of its contents and the range of the glycol mass?

    3

    A carpeted meeting room measuring 8 m by 12 m is cleaned with 0.5 L of liquid per square meter, and the recovery tank collects 33.6 L. What fraction is recovered and how many liters are left per square meter?

    Self-assessment progress0%