By Kurnia · Published November 11, 2026 · Version 1 · 21 min read
B3 waste in hotels, laundries, and workshops
identification and characteristics, packaging and symbols, temporary storage facilities, storage time limits, balances and manifests, and spills and emergency response
In the engineering workshop of a hotel, staff find drums of used oil with no labels, spent lamps in cardboard boxes, empty bleach jerry cans from the laundry, and oily rags in an ordinary trash bin. This chapter covers hazardous and toxic waste from the building technician’s side: recognizing its types and characteristics, packaging and labeling it, the requirements for a temporary storage facility, calculating the storage time limit from the date the waste is generated, building a waste balance and reconciling manifests, and handling spills. The technical requirements whose text can be opened are the annexes of Minister of Health regulations for health care facilities, used as a comparison, with United States data for generator categories and waste characteristics. The environmental provisions that bind hotels, laundries, and workshops are checked with the regional environmental agency. Transport, treatment, and handling of large spills or unknown materials are work for licensed parties and the emergency response team.
This material involves real hazards. A concept explanation doesn’t replace site procedures, competency, energy isolation, the latest SDS, or a work permit.
The chief engineer of a hotel asks a technician to tidy the storeroom behind the workshop before an environmental audit. Inside are two drums of used generator oil with no labels, one of them without a lid, three cardboard boxes of spent tube lamps, a dozen or more empty bleach and softener jerry cans from the laundry, a cracked forklift battery, and an ordinary trash bin full of oily rags and sawdust. On the floor, old drips of oil have run toward a storm drain opening. Before touching anything, the technician needs to know which items count as hazardous waste, how to package and mark them, where and how long to store them, what records go with their handover, and what to do if the oil spills again.
Scope
This chapter covers B3 waste from the support activities of hotels, laundries, and workshops from the building technician’s side, from recognizing the waste to responding to a spill. Outside health care facilities, B3 waste management is governed by environmental regulations, namely PP 22/2021 (Government Regulation) and the ministerial regulations derived from it. As of November 2026, the content and status of its technical provisions could not yet be confirmed; the form of permits, symbols, and storage time limits for hotels is checked with the local regional environmental agency (dinas lingkungan hidup). The detailed requirements used here as an official comparison are the annexes of Permenkes (Minister of Health Regulation) 2/2023 and 7/2019 for health care facilities. Permenkes 3/2026 revokes both regulations except for several articles together with their annexes. United States data from the EPA are used to show how another country classifies generators and waste characteristics.
Labels and safety data sheets are in Chapter 6 · Safety on chemicals in a technician’s work, incompatibility in Chapter 25 · Chemistry on chemical reactivity and incompatibility, and incident investigation in Chapter 12 · Safety on incident investigation. Used oil and used cooking oil are covered in more detail in Chapter 34 on used cooking oil, grease, and used oil, ordinary trash in Chapter 33 on solid waste in hotels, laundries, and kitchens, medical waste in Chapter 36 on hospital medical waste, and laundry wastewater in Chapter 17 · Laundry on laundry wastewater and the IPAL.
Work outside the technician’s authority: transporting B3 waste off site, treating, burning, or landfilling B3 waste, mixing or neutralizing waste, opening a drum that is bulging or holds an unknown material, cleaning up a large spill or an unknown material, and repairing a damaged battery. That work belongs to licensed transporters and processors and to the designated emergency response team. The technician recognizes, segregates, packages, and labels waste, looks after the storage facility, fills in the records, and handles small, known spills with the spill kit provided.
What counts as B3 waste and where it comes from
Hazardous and toxic materials (B3, from the Indonesian bahan berbahaya dan beracun) are substances, energy, or other components that, because of their nature, concentration, or quantity, can pollute or damage the environment and endanger the health and survival of humans and other living things. Hazardous and toxic waste (Indonesian limbah B3) is the residue of a business or activity that contains B3, while non-B3 waste is residue that does not show the characteristics of B3 waste. The definition centers on what the waste contains: an empty jerry can is still B3 waste if it holds residue of a hazardous material, and a rag becomes B3 waste once it has absorbed oil or solvent.
The list of hospital B3 waste in Permenkes 7/2019 includes many types that also occur in hotels, laundries, and workshops: spent batteries, used oil, used oil filters, spent lamps, used paint containers for paints that contain toxic substances, used chemical containers, used printer cartridges, and used computer circuit boards. In a hotel the sources are scattered: the workshop produces oil, filters, rags, and batteries; the laundry produces used chemical jerry cans and drums, expired product, and spill absorbents; the office produces cartridges and batteries; lamp replacement produces spent tube lamps.
The United States EPA allows spent lamps that qualify as hazardous waste, for example fluorescent lamps, high intensity discharge lamps, mercury vapor lamps, and high pressure sodium lamps, to be managed under special rules called universal waste, together with batteries, mercury-containing equipment, pesticides, and aerosol cans. That grouping is specific to the United States, but the lesson applies generally: spent lamps and batteries are not thrown out with ordinary trash.
Identification and characteristics
Permenkes 7/2019 calls for identification by the unit in charge of environmental health together with the units that generate waste, covering the type of waste, characteristics, source, volume generated, method of containment, method of transport, method of storage, and method of treatment, with the results documented. In a hotel, the same structure is used for a waste list per department; without that list there is no basis for choosing containers, calculating storage time limits, or reconciling manifests.
A hazardous waste characteristic is a measurable property that makes a waste count as hazardous. The EPA sets four characteristics: ignitability, corrosivity, reactivity, and toxicity. In the United States, a liquid waste with a flash point below 60 °C is ignitable, and an aqueous waste with a pH less than or equal to 2 or greater than or equal to 12.5 is corrosive. Those figures are United States thresholds, not Indonesian ones, but they show that characteristics are determined by measured tests, not by smell or color.
For the technician, the first source of information is the label of the original product and its safety data sheet, especially the sections on hazard identification, stability and reactivity, and disposal considerations (Chapter 6 · Safety on chemicals in a technician’s work). Waste of unknown origin is not guessed from its appearance or smell. It is marked “not yet identified,” stored separately, and its identification is handed to the environmental officer, who can ask a licensed processor or a laboratory for help.
Packaging, labels, and symbols
B3 waste containers in the source room must be strong, rust-resistant, watertight, made of easily cleaned material, fitted with a lid and the B3 symbol, and placed out of reach of the general public. Containers in the source room also carry the words “B3 waste” and its symbol, an eyewash, and a simple logbook, and are cleaned periodically. Liquid chemical waste is held in a strong container made of a material able to withstand the properties of that waste, and chemical wastes of different composition are kept separate to avoid unwanted reactions.
In the storage facility, each type of B3 waste is placed in a separate container, and the container is given a label, a B3 waste symbol matching its properties, and an arrow showing the closure direction, in the size and shape set by the standard. The area where the containers stand is given a sign naming the type of waste. The closure arrow prevents a liquid container from being laid on its side and leaking through its lid.
A B3 waste symbol is an image that states the characteristic of the waste in a container, while a B3 waste label is written information on the contents and origin of that container. For health care facilities, Permenkes 7/2019 lists the radioactive, infectious, and cytotoxic symbols, and the toxic, flammable, mixed, or hazard-specific symbols for chemical waste. WHO recommends a label recording the area of origin, the date and time the container was closed, and the name of the person filling in the label, plus an international hazard symbol. The shape, color, and size of B3 waste symbols for hotels are set by environmental regulations; use the examples from the regional environmental agency or a licensed processor, not homemade drawings.
The hazard pictograms on a bleach jerry can describe its original contents. Once the jerry can becomes waste, a waste label is added without covering the product label, because the product label is still a guide to the characteristics for the processor.
Temporary storage facility
A B3 waste temporary storage facility (B3 waste TPS, from the Indonesian tempat penyimpanan sementara) is an enclosed building or room where B3 waste is stored before licensed parties transport, treat, or landfill it. The annex of Permenkes 2/2023 contains TPS requirements for health care facilities. This table summarizes them as a comparison for a hotel, laundry, or workshop TPS.
| Element | Requirement in the annex of Permenkes 2/2023 |
|---|---|
| Location | in the service area, free from flooding, not close to service activities or residential areas |
| Building | enclosed, with a door, adequate ventilation, an exhaust fan, a drain to a control pit or the wastewater management system, vehicle access |
| Room division | separate rooms for infectious waste, liquid noninfectious waste, and solid noninfectious waste; placement grouped by characteristic |
| Liquid waste | leak-proof drums on an impermeable floor with a channel and a bund to contain spills |
| Solid waste | strong, watertight, corrosion-resistant, easily cleaned containers or drums, on pallets |
| Container placement | spacing between containers of about 50 cm; every container labeled and marked with a symbol |
| Security | fence, padlock, outdoor lighting, emergency telephone numbers for security, the fire department, and the police |
| Signs and documents | a “TPS Limbah B3” sign, a no-entry sign for unauthorized persons, symbols for the type of waste, location coordinates, standard operating procedures (SPO) for handling and for emergencies, and a logbook |
WHO adds general requirements: a hard, impermeable floor with good drainage, water for cleaning, lockable, inaccessible to animals, not near food stores or food preparation areas, and spill containment equipment. Distance from food matters in a hotel, because the storeroom behind the kitchen is often shared.
For the building technician, the TPS requirements are an infrastructure checklist: the lights and exhaust fan work, the door locks, the floor is not cracked, the floor drain of the TPS does not discharge to the storm drain, the bund does not leak, and the pallets are not rotting. For health care facilities, a TPS needs a technical approval from the authorized government agency, and that approval is renewed before it expires. The form of permit or approval for a hotel TPS is checked with the regional environmental agency.
Storage time limits and how to calculate them
The storage time limit is the longest time B3 waste may stay in the TPS before it is handed to a transporter, processor, or landfill operator. The annex of Permenkes 2/2023 sets storage time limits for B3 waste at health care facilities other than infectious, sharps, and pathological waste, for example expired chemicals, spills, packaging residue, equipment with a high heavy metal content, and pressurized cylinders. The limit is at most 90 days for B3 waste generated at 50 kg per day or more, and 180 days for category 1 B3 waste generated at less than 50 kg per day, counted from the date the B3 waste is generated. The meaning of “category 1” is not explained in that annex. Storage time limits for hotels, laundries, and workshops follow environmental regulations and are checked with the regional environmental agency.
The average generation rate is calculated from the weighing records:
where is the average generation rate (kg/day), is the mass of B3 waste generated during the observation period (kg), and is the number of days in that period. A period that is too short is misleading because of peaks, for example a generator oil change. The storage deadline is counted from the date the first waste enters the container, not from the date the container is full:
where is the date the first waste is generated or put into the container and is the applicable storage time limit (days). The container label records the start date, and collection is scheduled before with a time margin.
As a comparison, the EPA classifies hazardous waste generators by monthly quantity. Very small quantity generators produce 100 kg per month or less, small quantity generators more than 100 kg but less than 1,000 kg per month, and large quantity generators 1,000 kg per month or more. Small quantity generators may store on site for up to 180 days with no more than 6,000 kg. Large quantity generators may store for up to 90 days only. The direction is the same as the Indonesian comparison: a larger generator gets a shorter storage time.
Balances, records, and manifests
A B3 waste balance is a record of the balance between the waste generated, the waste handed over, and the waste still in storage during a period:
where and are the amounts of waste in the TPS at the start and end of the period, is the amount generated, and is the amount handed to the transporter, all in the same unit (kg or liters). The balance is kept per waste type, because each type may be handed to a different party on a different schedule. If the physical weighing or measurement in the TPS differs from , the difference is traced: some waste was not recorded, was spilled, or left without documents.
The handover of waste from the source room to the waste officer comes with a handover record (berita acara) stating at least the day and date, location of origin, type, form, and volume of the waste, and its containment method. In the TPS, every container that enters and leaves is recorded in the B3 waste logbook.
A B3 waste manifest is the document that accompanies every shipment of B3 waste from the generator to the processor or landfill operator. For health care facilities, every shipment carries a manifest signed and stamped by the generator, the transporter, and the processor or landfill operator, then archived by the generator, or entered in the electronic recording system of the environment ministry. The generator also makes sure the transporter and processor hold permits matching the type of waste transported or treated, and that the type and license plate number of the vehicle match those in the transport permit. A B3 waste report is submitted at least once every three months, with the logbook and manifests attached.
In the United States, small and large quantity generators must use manifests and must report when the signed copies do not come back. Without that copy, the generator cannot prove that its waste reached the right place.
Spills and emergency response
A spill kit for B3 waste must always be available in the source room, complete with instructions for use and the material safety data sheet. The material from a spill cleanup is placed in a special container and treated as B3 waste, then recorded and reported to the relevant unit. Oily absorbent from an oil spill does not go into an ordinary trash bin.
WHO gives an example of a general sequence for dealing with spills in health care facilities, and that sequence can be used in workshops and laundries by adapting it to the material. The main steps:
- Move people away from the affected area, and immediately decontaminate the eyes and skin of anyone exposed.
- Inform the designated person who coordinates the response.
- Identify the spilled material; if it is particularly hazardous, evacuate everyone not involved in the cleanup.
- Give first aid to anyone injured, and secure the area so that no one else is exposed.
- Wear suitable protective clothing, limit the spread of the spill, then collect the spilled material and the cleaning material into the appropriate waste container.
- Clean the area from the least to the most contaminated part, clean the tools, remove the protective clothing, and report the incident.
For a splash of corrosive material into the eyes, WHO states continuous rinsing with clean water for 10 to 30 minutes. Large spills of hazardous chemicals are cleaned up by designated personnel specially trained for the purpose. The technician does not neutralize a spill on their own initiative; the neutralizing agent and the method are set by the safety data sheet and the authorized team (Chapter 6 · Safety on chemicals in a technician’s work).
Drains are the fastest route for a spill to spread. Liquid chemicals should not be discharged to the wastewater pipe network, because their toxicity can disturb the biological process in wastewater treatment. A storm drain is even more dangerous because it discharges directly to the environment, so the technician checks floor drain covers, the TPS bund, and the absorbent near the drums routinely. Permenkes 7/2019 also calls for emergency procedures for B3 waste handling in case of fire and disasters, including emergency arrangements with transporters and processors when the routine system is disrupted.
Worked example
The figures in the examples below are practice figures, unless their origin is stated.
Example 1: a one-month used oil balance. At the start of March, the workshop TPS holds 120 L of used oil. During March, oil comes from two generator oil changes of 18 L each, a compressor at 8 L, and four vehicles at 4.5 L each, so L. The licensed transporter collects 150 L. The final balance is L. With a used oil density of 0.88 kg/L, the oil generated that month is kg and the final amount is kg. A physical drum measurement of 32 L means the balance matches.
Example 2: generation rate and comparison. In one 30-day month, the hotel generates 54.6 kg of used oil, 12 kg of spent lamps, 38 kg of used chemical jerry cans and drums, 9 kg of contaminated rags and absorbents, and two spent batteries weighing 28 kg. The total is kg, and the average rate is kg/day. Against the health care facility comparison, this rate is far below 50 kg per day. In the United States, 141.6 kg per month exceeds 100 kg, so the generator is a small quantity generator. Different comparisons give different conclusions, so the applicable provision is checked with the regional environmental agency.
Example 3: the storage deadline. The first oil is poured into a new drum on March 3, 2026, and that date is written on the label. With a 180-day limit, the days remaining in March after the 3rd are 28, then April 30, May 31, June 30, and July 31, totaling days. The remaining days fall on August 30, 2026. With a 90-day limit, days run to May 31, so the deadline is June 1, 2026. Collection is scheduled several weeks before the deadline, not on the last day.
Example 4: the height of a bund for oil drums. The hotel policy in this exercise: the bund holds the full contents of one leaking 200 L drum. The inside area of the bund is 2.4 m by 1.2 m, or 2.88 m², and four drums 0.58 m in diameter stand inside it. The footprint of one drum is m², of four drums m², so the net containment area is m². The liquid height for 0.200 m³ is m, or about 11 cm. All four footprints are counted because the leaking drum still stands in place. A 15 cm bund leaves free space for splashing and cleaning water.
Example 5: how many drums fit along one wall. A 4.0 m TPS wall is used for drums 0.58 m in diameter with a spacing between containers of about 50 cm. For drums the length needed is m, so and . At most 4 drums fit, using m. A fifth drum needs another wall or more frequent collection, not narrower spacing.
Example 6: reconciling manifests. The hotel logbook records three shipments in one quarter: 140 kg, 96 kg, and 176 kg, totaling 412 kg. The manifest copies returned by the processor record 138 kg, 96 kg, and 158 kg, totaling 392 kg. The quarterly difference is kg, or percent. The difference for the third shipment is kg, or percent, much larger than for the other two. The third shipment is traced with the transporter: a different scale, a container recorded twice, or waste that never arrived.
Stop conditions
- A container has no label or its contents are unknown: do not open, sniff, combine, or pour it; mark it, separate it, and hand its identification to the hotel environmental officer, who can ask a licensed processor or a laboratory for help.
- A drum or jerry can is bulging, hot, smoking, hissing, or leaking from its lid: do not open or move it; keep people away, report to the emergency response team, and call the fire department if there are signs of a reaction or fire.
- A spill has entered a storm drain, a gutter, or a drain leading to the wastewater treatment plant (IPAL), is larger than the spill kit can handle, or involves an unknown material: stop cleaning up on your own, secure the area from a safe distance, and hand over to the emergency response team and the environmental officer for reporting to the authorized agency.
- Someone has been splashed in the eyes or on the skin, is short of breath, or is dizzy after handling waste: stop the work, rinse and give first aid according to the safety data sheet, then take the person to a health worker.
- A lamp is broken, or a battery is cracked or leaking electrolyte: stop normal handling; have it handled as a spill by a trained person, and hand the battery to a licensed collector without repairing it.
- The TPS is full or the storage time limit of a container is about to be exceeded: do not move the waste to another storeroom or into a trash bin; report to management for collection by a licensed transporter.
- The transporter cannot show a permit matching the type of waste, the vehicle does not match the permit, or the manifest has not been filled in: do not hand over the waste; report to the environmental officer.
- The technician is asked to mix, neutralize, burn, landfill, or pour B3 waste into a drain: refuse, and leave treatment to a licensed processor.
Common misinterpretations
Guess what’s wrong first, then open the explanation.
Common misconception
An empty jerry can is not B3 waste.
Why is it wrong?
A used chemical jerry can still holds residue of the product. Used chemical containers are listed as B3 waste and kept separate from ordinary trash.
Common misconception
The storage time limit starts when the drum is full.
Why is it wrong?
The storage time limit counts from the date the B3 waste is generated. A drum that fills slowly is the one most likely to pass its deadline, so the start date is written on the label.
Common misconception
Used oil is sold to a collector, so it is not waste.
Why is it wrong?
Used oil remains B3 waste while it is stored and handed over. The receiving party must hold a permit matching the type of waste, and every shipment comes with a manifest.
Common misconception
A small spill can be hosed into the gutter.
Why is it wrong?
Water spreads the material into the drains and the environment. A spill is absorbed with the spill kit, and the absorbent is treated as B3 waste.
Common misconception
The manifest is the transporter’s business.
Why is it wrong?
The generator also signs and archives the manifest, and it is the generator who traces a copy that does not come back from the processor or a figure that differs.
Links to other chapters
Chapter 6 · Safety on chemicals in a technician’s work covers materials that are still products, and Chapter 25 · Chemistry on chemical reactivity and incompatibility is the basis for separating containers in the TPS. Chapter 34 on used cooking oil, grease, and used oil details used oil, and Chapter 36 on hospital medical waste uses a similar TPS for infectious waste. Spills or manifest differences are investigated in the way described in Chapter 12 · Safety on incident investigation. Fire protection of the TPS is in Chapter 17 · Buildings & Facilities on inspection-level fire protection, and work permits for repairs inside the TPS in Chapter 76 · Electrical & Control on safe work.
Exercises and worked solutions
The figures in the exercises are for practice.
Try to answer first, then open the worked solution.
A hotel laundry generates 18 kg of B3 waste per week, and its TPS can hold 300 kg. With a comparison storage time limit of 180 days, which constraint limits the collection schedule first?
Check my answer
See the worked solution
The average rate is kg/day, so the TPS fills in days. That 117 days is shorter than 180 days, so the TPS capacity is the first limit, and collection is scheduled at intervals shorter than 117 days.
The first spent lamp is put into a storage box on January 15, 2026. When is the deadline with a 90-day limit, and why is that date written on the label?
Check my answer
See the worked solution
The days remaining in January after the 15th are 16, February has 28, and March 31, totaling 75 days, so day 90 falls on April 15, 2026. The start date is written on the label because the storage time limit counts from the date the waste is generated, and without that date the deadline cannot be checked.
A technician finds an unlabeled jerry can holding a sharp-smelling liquid behind the laundry. What is done?
Check my answer
See the worked solution
The jerry can is not opened, sniffed, or poured, because its contents are not yet identified and may react or be toxic. The technician marks it, moves it away from other materials if it is safe to do so, and reports it to the environmental officer for identification.
Contaminated rag balance: opening amount 45 kg, generated 30 kg, handed over 60 kg, and physical weighing 12 kg. What is the conclusion?
Check my answer
See the worked solution
By the balance, the final amount is kg, while the physical weighing is 12 kg, so there is a difference of 3 kg. The difference is traced, for example rags thrown into an ordinary trash bin or a different scale, because a balance that does not match means some waste left without a record.
About 5 L of oil spills on the workshop floor and starts flowing toward a storm drain opening. What is the sequence of actions?
Check my answer
See the worked solution
The flow into the drain is stopped first with absorbent or a drain cover from the spill kit, because a storm drain discharges directly to the environment. The area is secured, the spill is absorbed and collected into a B3 waste container, and the incident is reported; if oil has already entered the drain, the emergency response team and the environmental officer take over.
The transporter’s truck arrives with a license plate number different from the one in its permit. What does the technician decide?
Check my answer
See the worked solution
The waste is not handed over, because the type and license plate number of the vehicle must match the transport permit. The technician reports to the environmental officer, who contacts the transporter to send a matching vehicle.
References
External sources
- Peraturan Menteri Kesehatan Nomor 2 Tahun 2023 tentang Peraturan Pelaksanaan Peraturan Pemerintah Nomor 66 Tahun 2014 tentang Kesehatan Lingkunganjdih.kemkes.go.id
- Peraturan Menteri Kesehatan Nomor 7 Tahun 2019 tentang Kesehatan Lingkungan Rumah Sakitjdih.kemkes.go.id
- Peraturan Menteri Kesehatan Nomor 3 Tahun 2026 tentang Penanggulangan Penyakitjdih.kemkes.go.id
- Safe management of wastes from health-care activitiesiris.who.int
- Defining Hazardous Waste: Listed, Characteristic and Mixed Radiological Wastesepa.gov
- Categories of Hazardous Waste Generatorsepa.gov
- Hazardous Waste Generator Regulatory Summaryepa.gov
- Universal Wasteepa.gov
Revision history
| Date | Version | Change |
|---|---|---|
| November 11, 2026 | 1 | First published |
How to cite
Kurnia (2026). B3 waste in hotels, laundries, and workshops: identification and characteristics, packaging and symbols, temporary storage facilities, storage time limits, balances and manifests, and spills and emergency response. ARSTEMA Academy. Revised November 11, 2026. arstema.com/en/academy/konsep/limbah-b3-di-hotel-laundry-dan-bengkel-identifikasi-dan-karakteristik-kemasan-dan-simbol-tempat-penyimpanan-sementara-masa-simpan-neraca-dan-manifes-serta-tumpahan-dan-tanggap-darurat
Self-check · 3 questions
Check your understanding before moving on
Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.
Safety limits still apply. This quiz tests reasoning; it doesn’t authorize mixing, adjusting, dismantling, live measurement, or field action.
A hotel laundry generates 18 kg of B3 waste per week, and its TPS can hold 300 kg. With a comparison storage time limit of 180 days, which constraint limits the collection schedule first?
The first spent lamp is put into a storage box on January 15, 2026. When is the deadline with a 90-day limit, and why is that date written on the label?
A technician finds an unlabeled jerry can holding a sharp-smelling liquid behind the laundry. What is done?
Nearby chapters
Reading order by shelf: Water & Water Treatment · Chapter 36.
Reading order by shelf: Water & Water Treatment · Chapter 34.
Another chapter in Water & Water Treatment.