A cook slips in a hotel kitchen that has just been laid with glossy tiles, and several tiles in front of the oven sound hollow. This chapter covers floors from the building technician’s side: the floor finish as a layered system, ceramic tiles and granite tiles on floors in use, adhesive, grout, and movement joints, how to map hollow tiles and read lifted tiles, falls on wet floors and ponding, and slippery floors and friction testing according to the technical sheet of the UK HSE (pendulum test value, Rz roughness, and ramp test classes). Repair is written with its limits: silica dust from cutting and grinding (the NAB in Permenaker 5/2018 and the UK exposure limit), suspected asbestos in old vinyl tiles and adhesive, the ban on hydrofluoric acid etching products, and stop conditions when a floor lifts under pressure or a structural problem is suspected.
A month after a renovation, a hotel kitchen had polished granite tiles in place of the old dull tiles. During the dinner rush, a cook slipped near the dishwasher, where water and leftover oil always drip onto the floor. The same week, the cleaning staff reported that several tiles in front of the oven sounded hollow when a trolley rolled over them, and one tile corner had already cracked.
The building technician who was called faced three questions. Is that tile surface suitable for a floor that is always wet and oily? What does the hollow sound mean? Does the water run to the drain or pond in the path where people walk? The answers are read from observation, simple measurements, and the right test results, not from how the tiles look.
Scope
This chapter covers finished floors from the building technician’s side: recognizing floor finishes, inspecting tiles, adhesive, and grout, mapping hollow and lifted tiles, measuring falls and ponding, reading slip test results, and assigned light repair. Structural assessment and structural change, removal of materials suspected to contain asbestos, and work that the rules reserve for an expert or a contractor are written as limits and stop conditions.
Tile material properties, layer build-ups, and basic drilling are in Chapter 3 on drilling, tile materials, and basic plumbing; this chapter does not repeat them. Mold on grout is in Chapter 9 · Biology & Microbiology on mold in buildings, the hydraulics of floor drains in Chapter 10 on drainage hydraulics, cracks in concrete in Chapter 36 on cracks in walls and concrete, and paint-based floor coatings in Chapter 37 on building paints and coatings.
The building technician does not assess the strength of the floor slab, does not take up a floor that has lifted under pressure from below, and does not use etching products or anti-slip coatings without an assessment by the person responsible for K3 (occupational safety and health).
The floor finish as a layered system
A floor finish is the top layer of a floor that is walked on and cleaned, for example ceramic tile, porcelain tile, natural stone, terrazzo, resin flooring, vinyl, or carpet. Below it is adhesive or mortar, often a leveling layer (screed), and then the concrete slab. Chapter 3 on tile materials explains that build-up; the consequence for inspection is that a symptom at the surface can come from any layer, so a cracked tile is not necessarily a problem with the tile itself.
Each type of finish raises different maintenance questions. Tiles and natural stone are checked for bond, grout, and slipperiness; resin floors are checked for peeling and wear; vinyl and carpet are checked for seams and lifted edges, which easily make people trip.
Old floor finishes can also hide hazards that cannot be seen. In the UK, asbestos was once added to PVC and thermoplastic floor tiles, to bitumen adhesive used to stick floor tiles down, and to paper-backed floor coverings, and such old tiles can be hidden under carpet. In the UK, grinding off such flooring materials is work that must be done by a licensed contractor. In older buildings in Indonesia, vinyl tiles or black adhesive that have not been tested are treated as suspect until a material test result is available.
Ceramic tiles and granite tiles on floors in use
In the Indonesian market, a granite tile (ubin granit) usually means a homogeneous porcelain tile that is densely pressed and often polished, not natural granite cut from stone. Both are hard and wear resistant, but the polished surface of both is smooth.
Uneven traffic causes uneven wear, for example at doorways that are stepped on most often. Floor tiles also crack and break easily when something heavy is dropped on them, when heavy objects or trolleys pass over them repeatedly, or when they are exposed to heavy vibration. In kitchens and laundries, trolley routes and the spots where pans are dropped are the first places to inspect.
HSE notes that the largest improvement in slip resistance after etching is usually seen on very smooth materials, such as highly polished granite or marble and glazed ceramic tiles. In other words, it is those very smooth surfaces that call for caution when wet, and a glossy tile that works well in a lobby can become a high-risk floor in a kitchen that is always wet.
Adhesive, grout, and movement joints
Tiles stay in place because of the bond between the tile, the adhesive or mortar, and the layer below. When the adhesive does not cover the whole back of the tile, a void forms, and a concentrated load such as a trolley wheel bends the tile over that void until it cracks. The durability of a tile floor depends to a great extent on a sound mortar bed and sound grout joints; mortar of the wrong type or inadequately mixed mortar is a source of trouble.
Grout fills the gaps between tiles, but ordinary grout is not a waterproof layer. Water that is allowed to sit around showers and bathtubs eventually damages the grout and mortar and loosens the tiles. Damaged grout can still be repaired: the floor is first checked for loose tiles, the damaged grout is removed by hand, and the joints are wetted or given a bonding agent before being filled with grout that matches in color and consistency.
The tile, adhesive, and slab layers expand and shrink by different amounts. The free elongation of a tiled field, according to Chapter 11 · Physics on thermal expansion, is
where is the elongation (m), the coefficient of linear expansion of the material (1/K), the length of the field (m), and the temperature rise (K). The formula assumes the field is free to move and the temperature is uniform. When the tiles heat up more than the slab below, the difference in elongation has to be taken up by a movement joint. A lack of movement joints is one of the major causes of cracked, broken, or debonded tiles.
Hollow and lifted tiles: reading the symptoms
A hollow-sounding tile is a tile that gives a hollow sound when tapped lightly or rolled over, because there is a void or a lost bond beneath it. The hollow sound is a symptom, not a measurement: tapping does not measure the bonded area, as noted in Chapter 3 on tile materials. A hollow tile that is not cracked and does not rock can last a long time, while a hollow tile on a trolley route cracks sooner.
The technician draws a plan of the tile grid, taps every tile with a light hard object, and marks the ones that are hollow, cracked, or rocking. The pattern gives clues. Hollow tiles scattered at random more likely come from adhesive that did not give full coverage. Hollow tiles grouped near a glass wall, above a hot pipe route, or along one line point to a cause that covers the whole field, such as heat, slab movement, or water from below.
A lifted tile (ubin terangkat; arching or ridging) is the condition in which one tile or a row of tiles rises and separates from its bed to relieve compressive stress; repairing it usually means taking up and relaying many or all of the tiles in that field. A lifted tile is an immediate trip hazard, and a field that still holds stress can keep moving. A floor that lifts under pressure from below, for example water coming out of the grout, a warm floor above a pipe route, or a floor that rises together with a crack in the slab, is no longer a tile problem.
Falls on wet floors and ponding
Floors that are often wet, such as kitchens, bathrooms, and laundry rooms, are laid to fall toward a floor drain. The fall is written in three equivalent ways:
where is the height difference (mm), the horizontal distance (mm), the fall in percent, and the angle. The formula assumes the floor is a flat plane between the two measuring points; a local dip between them is not picked up.
The fall of a wet floor is a compromise: water needs to run off quickly enough, but people walk more safely on a surface that is almost flat. The UK building rules for buildings other than dwellings call a route surface level when the gradient along the direction of travel is at most 1:60, and ask for the floor of a wheelchair-accessible shower to be slip resistant and self-draining. For impervious surfaces outside buildings, the UK drainage document recommends a gradient of at least 1 in 60 and a cross gradient on a path of no more than 1 in 40. Those figures are not design values for kitchen floors in Indonesia; the value that applies to a given building is taken from its design drawings.
Ponding occurs when a point is lower than a point between it and the drain. The technician measures the height of several points relative to the drain cover with a water tube level, a long spirit level, or a laser level, and compares the readings with the design fall. The depth of the pond is roughly the height difference between the lowest point and the sill that holds the water back. Repeated ponding keeps grout permanently damp, where mold grows according to Chapter 9 · Biology & Microbiology, and becomes a permanent slippery spot.
Slippery floors and friction testing
HSE notes that slips and trips are the most common cause of injury at work in the UK, and that most slip accidents happen when floors are contaminated with water, talc, or grease. The HSE slip potential model includes the factors floor material, contamination, footwear, cleaning, environment, use, and behavior.
The coefficient of friction (CoF) is the ratio of the friction force to the normal force, as covered in Chapter 4 · Physics on friction. Its value depends on how it is measured. HSE uses the pendulum test, in which an imitation heel with a standard rubber sole swings and sweeps across the floor; the result is read as the pendulum test value (PTV), and the test is the subject of the British Standard BS 7976. Slider 96 rubber is used for shod pedestrians and Slider 55 for barefoot areas. It is complemented by a surface microroughness meter, which reads Rz, the mean of several peak-to-valley distances, as an indication of slipperiness on water-wet floors.
| HSE classification | PTV | Rz, water-wet floor |
|---|---|---|
| High slip potential | 0 to 24 | below 10 µm |
| Moderate slip potential | 25 to 35 | 10 to 20 µm |
| Low slip potential | 36 and above | 20 µm and above |
Those Rz limits apply to water. A more viscous contaminant, such as oil, needs a rougher surface to keep the same slip resistance. The pendulum test must be run and interpreted by a trained and competent person. The building technician reads the test report rather than judging slipperiness by rubbing a shoe on the floor.
Many European manufacturers classify tiles with a ramp test: a test subject walks on a flooring sample whose inclination is raised until they slip, and that angle is converted into a coefficient of friction. The German standard DIN 51130 uses cleated safety boots with motor oil and gives classes from R9 (an angle of 6 to 10 degrees) to R13 (above 35 degrees); DIN 51097 uses bare feet with a soap solution. HSE has reservations about both methods because their contaminants are not representative of workplaces, notes that R9 or in some instances R10 floors will be slippery when wet or greasy, and that the R10 class covers a coefficient of friction from 0.18 to 0.34.
Manufacturers’ data are usually measured on new products as supplied from the factory, and slipperiness can change significantly through installation, grouting, cleaning, polishing, and short periods of use; data quoted only as CoF without the name of the test should be viewed with doubt. A 1996 NPS preservation brief cites the recommendation of the United States ADA guidelines of a static coefficient of friction of 0.6 for level surfaces and 0.8 for ramps. That figure comes from a test method different from the PTV, and its current status cannot be confirmed, so it is not used as a pass criterion.
Controlling slippery floors
The order follows the hierarchy of controls in Chapter 2 · Safety: remove contamination first, then change the surface, with footwear as an extra layer. For kitchens, HSE advises maintaining equipment so it does not leak, using drainage channels and drip trays from tilting kettles and bratt pans, keeping the extraction system for steam and grease working, and laying mats so that water is not carried in on shoes. A surface that is rough enough keeps its grip when wet, but loses that grip if it is not cleaned properly; the time the detergent stays on the floor has the biggest effect on cleanliness.
Floors are dried after cleaning; when that is not possible, put up barriers and wet floor signs, and remove the signs once the floor is dry. Slopes need more grip than level floors, especially when heavy goods are carried up or down them. Rubber soles offer more slip resistance on wet floors than polyurethane soles, and in the UK anti-slip footwear that is needed as personal protective equipment is paid for by the employer.
When cleaning and maintenance are not enough, the surface can be roughened or the finish replaced. HSE notes that etching fluids for ceramic tiles, terrazzo, and natural stone are normally based on hydrofluoric acid (HF), which is hazardous even at very low concentrations because exposure through the skin and by inhalation can cause necrosis of skin and bone and damage to organs, and that ammonium bifluoride in a safety data sheet indicates the presence of HF. Diamond grinding and shot blasting roughen the surface without etching, but they produce dust that must be controlled. That choice is made by the building manager together with the person responsible for K3 and the flooring contractor.
Tile repair from the building technician’s side
The first step in a repair is to make the floor safe to cross: put up barriers around lifted or broken tiles and divert trolleys. The second step is to find the cause. When the damage is more than normal wear, the source of the problem needs to be identified and corrected before tiles are replaced, and a successful replacement depends on the condition of the bed the tiles are laid on, not only on finding matching replacement tiles. New tiles on a slab that is still moving can become hollow again.
Replacing a single tile easily damages the tiles next to it. Hammer and chisel often fail because the shock of the blows travels through the grout into the surrounding tiles and cracks them; all the grout around the tile is first removed by an experienced tile installer with a grout saw, or with a diamond blade for wide joints. A new tile of different thickness needs a bed at a different height, and two beds of different hardness can create new problems.
Cutting, grinding, and drilling tiles, grout, and concrete produce respirable crystalline silica (RCS), silica particles fine enough to get deep into the lungs. According to HSE, concrete and mortar contain 25 to 70 percent silica, brick and granite up to 30 percent, and limestone and marble up to 2 percent; long-term exposure causes silicosis, a hardening of lung tissue that cannot be reversed. The UK workplace exposure limit for RCS is 0.1 mg/m³ as an 8-hour time-weighted average. In Indonesia, Permenaker 5/2018 (Minister of Manpower Regulation) on K3 in the work environment, which JDIH Kemnaker lists as in force as of November 13, 2026, sets an NAB (threshold limit value) for crystalline silica, quartz and cristobalite, of 0.025 mg/m³ for the respirable fraction.
Dust control starts with reducing the number of cuts. HSE names two main methods: water suppression supplied for the whole time the work is done, because just wetting the material beforehand does not work, and on-tool extraction with an H or M class extraction unit, not a general vacuum cleaner. Respiratory protective equipment with a protection factor of 20, for example an FFP3 disposable mask, is the last layer, and tight-fitting masks need face fit testing and a clean-shaven face. How to choose a mask is in Chapter 5 · Safety on personal protective equipment.
Worked example
The numbers in the examples below are practice values unless their origin is stated.
Example 1: a map of hollow tiles in a hotel lobby. A lobby field of 6.0 m by 4.8 m laid with 60 cm by 60 cm tiles contains tiles. Tapping marks 14 hollow tiles, which is percent. Nine of them are grouped in three rows near a glass wall, covering m², and five are scattered. The percentage alone decides nothing; the group near the glass points to a cause that covers the field, such as sunlight heating, while the scattered ones are more likely local adhesive voids.
Example 2: differential expansion in a hospital corridor. A tiled field 12 m long in a corridor with a glass wall has no movement joint. With 1/K and a tile temperature rise of 20 K, m, that is, 1.44 mm. The slab below rises by only 5 K with 1/K, so it lengthens by m. The difference of mm has to be taken up by the adhesive or becomes compression that can make a row of tiles lift.
Example 3: kitchen fall to a drain. The floor drain of a hotel kitchen is 2.4 m from the wall, and the drawing gives a fall of 1:80. The height difference is mm, the fall is percent, and the angle is degrees. A fall of 1:80 is shallower than the 1:60 level limit in the UK rules. To stand still on that slope, the coefficient of friction needed is only ; what makes the floor slippery is the film of water and oil, not the fall.
Example 4: ponding from point measurements. On the same line as in Example 3, the design heights at 0.6, 1.2, 1.8, and 2.4 m from the drain are , , , and mm. The readings relative to the drain cover are 8, 6, 21, and 30 mm. The point at 1.2 m (6 mm) is lower than the point at 0.6 m (8 mm) that lies between it and the drain, so water there is held until it rises by mm. That point is also 9 mm below the design height, and the finding is reported as ponding of about 2 mm on a walking route.
Example 5: converting a ramp test angle to a coefficient of friction. In a ramp test, the test subject slips at an angle , and the coefficient of friction is according to Chapter 4 · Physics on friction. The R10 class covers angles of 10 to 19 degrees, so and , matching the range of 0.18 to 0.34 noted by HSE. For R9, . The upper end of R10 is almost twice its lower end, so a single class label does not tell where a particular floor sits within that range.
Example 6: pendulum test results in a kitchen. A wet pendulum test report with Slider 96 at five points in a kitchen gives PTV 22, 31, 38, 27, and 45. According to the HSE table, 22 has high slip potential, 31 and 27 moderate, and 38 and 45 low. The PTV 22 point is in front of the dishwasher, and Rz there is 7 µm, also below 10 µm. Two different measurements point to the same conclusion, so the source of drips at that point is stopped first.
Stop conditions
- Tiles have lifted into a ridge, a popping sound has been heard, or the tiled field is still moving: put up barriers and divert traffic; do not step on, press, strike, or cut the tiles to release the pressure. Report to the building manager; the appointed flooring contractor assesses and takes up the tiles.
- A floor has lifted or sunk together with a crack in the concrete slab, a crack that continues into a wall or column, a sagging floor, or a door that suddenly sticks: stop the work and close off the area. The building manager hands it over to a structural engineer (Chapter 36 on cracks in walls and concrete).
- A floor has lifted or is wet because of pressure from below, for example water coming out of the grout with no source above it, or a warm floor above a pipe route: do not take up the tiles or open the pipes. Close off the area and hand it over to the person responsible for plumbing and utilities.
- Old vinyl or thermoplastic tiles, black bitumen adhesive, or paper-backed floor covering would be removed, ground, or drilled without a material test result: do not start. The building manager requests an asbestos survey by a competent party, and removal is done by an authorized contractor.
- Tiles, grout, or concrete would be cut, ground, or drilled without water dust suppression or on-tool extraction, without respiratory protection that has been selected and fit tested, or near patients and occupants without screening: do not start. The person responsible for K3 sets the dust controls.
- An anti-slip, etching, or cleaning product whose safety data sheet lists hydrofluoric acid or ammonium bifluoride, or whose contents are unknown: do not use it. The person responsible for K3 and the supplier assess it (Chapter 6 · Safety on chemicals in technicians’ work).
- A slippery floor that cannot be dried because of a continuous leak, or loose tiles on stairs and escape routes: close the route and put up signs. The building manager sets an alternative route, and the person responsible for plumbing stops the leak.
- Repairs in patient care rooms, procedure rooms, or production kitchens during service hours: postpone until the hospital infection prevention and control unit or the head chef sets the time, screening, and final cleaning.
Common misinterpretations
Guess what’s wrong first, then open the explanation.
Common misconception
A hollow sound means the tile is already loose and everything has to be taken up.
Why is it wrong?
The hollow sound marks a void, not its extent; the decision is made from the map, the pattern, cracks, and the cause, as in Example 1.
Common misconception
A lifted tile only needs to be stepped on or tapped flat again.
Why is it wrong?
A lifted tile is relieving compressive stress. Pressing it down does not remove the stress and can break the tile; the area is barriered off and handed over to the contractor.
Common misconception
A steeper fall is always better because water clears faster.
Why is it wrong?
A wet floor is a compromise between draining water and walking safely, and ponding often comes from a local dip, as in Example 4.
Common misconception
An R10 label or a friction figure in a brochure guarantees the floor is safe when wet.
Why is it wrong?
R classes are measured with oil and cleated boots, their range is wide, and factory data change after installation and cleaning. The installed floor is tested wet or contaminated as it is in use.
Common misconception
A cloth mask is enough for a short spell of grinding out grout.
Why is it wrong?
Respirable silica dust cannot be seen and its exposure limit is small. Dust is captured at the source with water or extraction, and respiratory protection is chosen by its protection factor.
Links to other chapters
Chapter 3 on tile materials gives the material properties and the layer build-up. Chapter 4 · Physics on friction and Chapter 8 · Units & Mathematics on field trigonometry explain the coefficient of friction and angles, Chapter 11 · Physics on thermal expansion explains the expansion of a tiled field, and Chapter 10 on drainage hydraulics explains floor drains. Silica dust relates to Chapter 36 · Biology & Microbiology on breathing and workplace air.
Exercises and worked solutions
The numbers in the problems are for practice.
Try to answer first, then open the worked solution.
Two adjacent 60 cm by 60 cm tiles in a hotel corridor are to be replaced. What length of grout has to be removed if both are replaced at once, compared with replacing them one at a time, and what tool is used?
Check my answer
See the worked solution
Replaced at once, the perimeter of the two tiles is m, while replaced one at a time it is m because the shared joint is opened twice. The grout is removed with a grout saw, not a hammer and chisel, so that the shock does not crack the surrounding tiles, and the cutting uses dust controls.
A shower area in a hospital bathroom falls at 1:50 to a drain 1.2 m away. What are the height difference and the fall in percent, and how does it compare with the 1:60 level limit?
Check my answer
See the worked solution
The height difference is mm and the fall is percent. That fall is steeper than the 1:60 level limit for routes, which is reasonable in a shower area that has to be self-draining, but that floor has to be slip resistant when wet and should not be a main route.
A ramp test report gives a slip angle of 27 degrees. What is the equivalent coefficient of friction, and why is that figure not compared directly with a PTV?
Check my answer
See the worked solution
The coefficient of friction is , at the boundary between classes R11 and R12. A ramp test uses people, footwear, and contaminants different from the pendulum test, so the results of the two methods are not converted into each other without a basis.
A cleaner has bought an anti-slip liquid whose safety data sheet lists ammonium bifluoride. How does the technician respond?
Check my answer
See the worked solution
HSE notes that ammonium bifluoride in a safety data sheet indicates hydrofluoric acid, which is hazardous even at very low concentrations. The technician stops its use, stores the container according to Chapter 6 · Safety, and hands the assessment to the person responsible for K3.
A row of tiles in a corridor has lifted, and nearby there is a crack in the concrete slab that continues into a column. What does the technician do?
Check my answer
See the worked solution
A slab crack that continues into a column is a suspected structural problem, so the tiles are not touched and the area is closed off. The building manager hands the assessment to a structural engineer, and the technician only records the location, photos, and time.
The brochure for tiles for a new kitchen gives class R10 and a dry PTV of 60. The kitchen is always wet and oily. Are these data enough to choose the tile?
Check my answer
See the worked solution
Not yet, because the R10 class covers a coefficient of friction of 0.18 to 0.34 and HSE notes that R10 floors are in some instances slippery when wet or greasy. A dry PTV does not describe a wet kitchen, so what is requested is a wet and contaminated PTV on a sample that has been installed and cleaned as it would be on site.
References
External sources
- Assessing the slip resistance of flooring: A technical information sheethse.gov.uk
- Preventing slips and trips in kitchens and food servicehse.gov.uk
- Slip resistance improvementshse.gov.uk
- Preservation Briefs 40: Preserving Historic Ceramic Tile Floorsnps.gov
- Construction dusthse.gov.uk
- Silicosis - causes and risk controlshse.gov.uk
- Peraturan Menteri Ketenagakerjaan Nomor 5 Tahun 2018 tentang Keselamatan dan Kesehatan Kerja Lingkungan Kerjajdih.kemnaker.go.id
- Approved Document M: Access to and use of buildings, Volume 2: Buildings other than dwellingsassets.publishing.service.gov.uk
- Approved Document H: Drainage and waste disposal, 2015 editionassets.publishing.service.gov.uk
- Locations of asbestos and taking the right actionhse.gov.uk
Revision history
| Date | Version | Change |
|---|---|---|
| November 13, 2026 | 1 | First published |
How to cite
Kurnia (2026). Floors and tiles: types of floor finish, ceramic and granite tiles, adhesive and grout, hollow and lifted tiles, falls on wet floors, slippery floors and friction testing, and repair. ARSTEMA Academy. Revised November 13, 2026. arstema.com/en/academy/konsep/lantai-dan-ubin-jenis-penutup-lantai-ubin-keramik-dan-granit-perekat-dan-nat-ubin-kopong-dan-terangkat-kemiringan-lantai-basah-lantai-licin-dan-uji-gesek-serta-perbaikan
Self-check · 3 questions
Check your understanding before moving on
Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.
Two adjacent 60 cm by 60 cm tiles in a hotel corridor are to be replaced. What length of grout has to be removed if both are replaced at once, compared with replacing them one at a time, and what tool is used?
A shower area in a hospital bathroom falls at 1:50 to a drain 1.2 m away. What are the height difference and the fall in percent, and how does it compare with the 1:60 level limit?
A ramp test report gives a slip angle of 27 degrees. What is the equivalent coefficient of friction, and why is that figure not compared directly with a PTV?