Skip to content

Search ARSTEMA

Type a chapter, term, symptom, or tool.

    Biology & Microbiology · Chapter 36Basic

    By Kurnia · Published November 10, 2026 · Version 1 · 21 min read

    Respiration and workplace air

    airways and alveoli, gas exchange, lung volumes, control of breathing by carbon dioxide, carbon monoxide and hemoglobin, irritant vapors and dust, and oxygen-deficient air

    Two ironer operators in a hotel’s basement laundry complain of headache, nausea, and difficulty concentrating without feeling short of breath, after the exhaust duct joint of a gas dryer was fitted loosely. This chapter explains how breathing works from the body’s side: the conducting zone and the alveoli, the mechanics of breathing and lung volumes, partial pressure and gas exchange, the transport of oxygen and carbon dioxide by the blood, the control of breathing by carbon dioxide, carbon monoxide and hemoglobin, the defenses of the airways against irritant vapors and dust, and oxygen-deficient air. Exposure limits are discussed through the definition of the threshold limit value in Permenaker 5/2018 and the values of United States agencies as US data. The chapter gives no diagnosis or treatment recommendations.

    High-risk material

    This material involves real hazards. A concept explanation doesn’t replace site procedures, competency, energy isolation, the latest SDS, or a work permit.

    Section you’re reading: Chapter opening

    In the laundry of a hotel that occupies the basement floor, the exhaust duct of one of the gas dryers has just been cleaned, and its joint behind the machine has been fitted loosely. Toward the afternoon, two ironer operators complain of headache and nausea, and one of them twice miscounts a stack of towels. There is no strange smell, the room does not feel stuffy, and nobody feels short of breath. The supervisor suspects they are short of sleep and overheated, then asks a technician to open the rear panel of the dryer. The technician arrives with a portable gas detector that reads 90 ppm of carbon monoxide near the exhaust duct joint. Why can air that feels ordinary make people dizzy without any feeling of breathlessness? The answer lies in how the lungs exchange gas, how the blood carries oxygen, and the signal the brain uses to regulate breathing; the decision for this case is in Example 6.

    Scope

    This chapter covers how breathing works and what it means for workplace air. Confined spaces, atmospheric testing, and rescue are in Chapter 11 · Safety; ppm calculations and steady-state ventilation in Chapter 11 · Chemistry on gas stoichiometry and hazardous gases; bioaerosols in Chapter 10; ventilation of laundry rooms and kitchens in Chapter 16 · Buildings & Facilities; carbon monoxide from equipment in Chapter 25 · Laundry on dryer gas burners and Chapter 1 · Commercial Kitchens on gas cooking equipment. Respiratory protection is in Chapter 5 · Safety on personal protective equipment, chemicals in Chapter 6 · Safety, and respiratory tract infections in Chapter 28. Chapter 37 on the heart and blood circulation covers the journey of blood from the lungs to the tissues.

    This chapter gives no diagnosis, drug recommendations, or medical limits for any particular person. Breathing complaints, dizziness, or nausea at work are examined by a doctor, the company doctor, or a healthcare facility.

    The airways: the conducting zone and the alveoli

    The respiratory system supplies oxygen for cellular respiration, removes carbon dioxide, and helps maintain acid-base balance. The conducting zone is the part of the airways that takes no part in gas exchange, from the nasal cavity, pharynx, larynx, trachea, and bronchi to most of the bronchioles; its job is to conduct air, remove debris and pathogens, and warm and humidify the air. The respiratory zone is the part of the lungs that exchanges gas directly, namely the respiratory bronchioles, alveolar ducts, and alveoli.

    The conchae in the nasal cavity enlarge the surface area and deflect the flow so that the air bounces against a ciliated epithelium containing mucus-producing goblet cells. The trachea is made up of 16 to 20 C-shaped rings of cartilage that keep it from collapsing. The bronchioles are about 1 mm in diameter, have no cartilage, and their muscular walls can change the size of the airway.

    An alveolus is a small elastic-walled sac where gas exchange takes place, about 200 µm in diameter. Up to 97 percent of its surface is lined with flat type I cells that gases pass through easily; type II cells produce surfactant, which lowers surface tension so that the alveolus does not collapse, and alveolar macrophages engulf debris that reaches it. The alveolar and capillary walls together form the respiratory membrane, an air-blood barrier about 0.5 µm thick that gases cross by simple diffusion. The gas-exchange surface area is about 70 m²; another estimate gives about 300 million alveoli in each lung with an area of about 75 m².

    The mechanics of breathing and lung volumes

    Air flows from high pressure to low pressure. Boyle’s law states that at constant temperature the pressure of a gas is inversely proportional to its volume:

    P1V1=P2V2P_1 V_1 = P_2 V_2

    where PP is pressure (mm Hg) and VV volume (L), with subscript 1 for the initial state and 2 for the final state. When breathing in, the diaphragm contracts and moves down, the external intercostal muscles raise the ribs, and the adhesive pleural fluid pulls the lungs along. The alveolar volume increases, its pressure drops slightly below atmospheric pressure, 760 mm Hg at sea level, and air flows in. Breathing out at rest is passive: the muscles relax and the elastic lung tissue recoils. Flow is also limited by airway resistance, F=ΔP/RF = \Delta P / R, where FF is flow, ΔP\Delta P the pressure difference, and RR the resistance, which is determined mainly by the diameter of the airway. A narrowed airway needs a larger pressure difference, that is, more work by the breathing muscles, for the same flow.

    The tidal volume is the air that enters the lungs during quiet breathing, about 500 mL. Total lung capacity is about 6,000 mL in men and 4,200 mL in women. For the average adult man, one table gives the following figures:

    Volume or capacityMeaningLiters
    Tidal volume (TV)air in one ordinary breath0.5
    Expiratory reserve volume (ERV)air that can still be breathed out after an ordinary exhalation1.2
    Inspiratory reserve volume (IRV)air that can still be breathed in after an ordinary inhalation3.1
    Residual volume (RV)air left after the most forceful exhalation1.2
    Vital capacity (VC = ERV + TV + IRV)the most air that can be moved in one cycle4.8
    Total lung capacity (TLC = RV + VC)air in the lungs after the deepest inhalation6.0

    These figures are averages, not benchmarks for judging a person’s lungs. Anatomical dead space is the air in the airways that never reaches the alveoli, so what determines gas exchange is alveolar ventilation:

    V˙E=f×VT,V˙A=f×(VT−VD)\dot V_E = f \times V_T, \qquad \dot V_A = f \times \left(V_T - V_D\right)

    where V˙E\dot V_E is minute ventilation and V˙A\dot V_A alveolar ventilation (L/min), ff the breathing rate (breaths/min), VTV_T the tidal volume, and VDV_D the dead space (L). The resting breathing rate of an adult is about 12 to 18 breaths per minute; another figure gives 12 to 15. Breathing that is too shallow mostly fills only the dead space (Example 2).

    Partial pressure and gas exchange

    Partial pressure is the pressure of one kind of gas in a mixture of gases. According to Dalton’s law, the total pressure of a mixture equals the sum of the partial pressures of its gases, so for gases that do not react with each other

    PO2=xO2×PtotalP_{\text{O}_2} = x_{\text{O}_2} \times P_{\text{total}}

    where xO2x_{\text{O}_2} is the dimensionless volume fraction of oxygen and PP is in mm Hg.

    GasOutside air, percentOutside air, mm HgAlveolar air, percentAlveolar air, mm Hg
    Nitrogen78.6597.474.9569
    Oxygen20.9158.813.7104
    Water vapor0.43.06.247
    Carbon dioxide0.040.35.240

    Alveolar air is more humid, richer in carbon dioxide, and poorer in oxygen than outside air because the air is humidified in the airways and the blood keeps taking up oxygen. The 47 mm Hg of water vapor in the airways takes its share of the total pressure, so the oxygen of inhaled air that has been humidified is about 150 mm Hg.

    Henry’s law states that the concentration of a gas dissolved in a liquid is proportional to its partial pressure and its solubility. Gas moves from high partial pressure to low. Alveolar oxygen is about 104 mm Hg and pulmonary capillary blood about 40 mm Hg, a difference of about 64 mm Hg. Blood carbon dioxide is about 45 mm Hg and alveolar 40 mm Hg, a difference of only 5 mm Hg, but its solubility is about 20 times that of oxygen, so the amounts of the two gases that cross are similar. In the tissues the direction is reversed: tissue oxygen is about 40 mm Hg and arterial blood about 100 mm Hg. This exchange also requires a match between ventilation, the flow of air to the alveoli, and perfusion, the flow of blood in the pulmonary capillaries; alveoli that receive less air are passed by less blood.

    Transport of oxygen and carbon dioxide

    Only about 1.5 percent of the oxygen in the blood is dissolved directly; about 98.5 percent is bound to hemoglobin, a red blood cell protein with four subunits, each carrying one iron-containing heme group for one oxygen molecule. The reaction is reversible, Hb+O2⇌HbO2\text{Hb} + \text{O}_2 \rightleftharpoons \text{HbO}_2, and the first oxygen that binds makes it easier for the next oxygen to bind. The percentage of heme groups carrying oxygen is called hemoglobin saturation, and in healthy people it is usually 95 to 99 percent.

    The relationship between saturation and the partial pressure of oxygen forms an S-shaped curve. Muscle working hard lowers its tissue oxygen to about 20 mm Hg so that more oxygen is released, and high temperature and a more acidic pH also speed up the release; this effect of pH is called the Bohr effect. Venous blood still carries a reserve of oxygen for tissues that suddenly need more.

    Carbon dioxide is transported about 70 percent as bicarbonate, about 20 percent bound to globin as carbaminohemoglobin, and 7 to 10 percent dissolved in plasma; another account gives 85, 10, and 5 to 7 percent. The enzyme carbonic anhydrase speeds up the reaction

    CO2+H2O⇌H2CO3⇌H++HCO3−\text{CO}_2 + \text{H}_2\text{O} \rightleftharpoons \text{H}_2\text{CO}_3 \rightleftharpoons \text{H}^{+} + \text{HCO}_3^{-}

    which reverses direction in the lungs. The hydrogen ions produced by this reaction are what link carbon dioxide to the acidity of the blood.

    Control of breathing by carbon dioxide

    The breathing rhythm is generated by the respiratory center in the medulla oblongata and regulated by centers in the pons. Its main stimulus is not the oxygen level but the carbon dioxide level of the blood. Carbon dioxide crosses the blood-brain barrier, raises the hydrogen ions in the brain fluid, and stimulates the central chemoreceptors in the brainstem, so that breathing becomes faster and deeper. The peripheral chemoreceptors in the carotid arteries and the aortic arch increase breathing only when blood oxygen falls to about 60 mm Hg or less, and they measure only the dissolved oxygen, not the oxygen bound to hemoglobin. Hyperventilation is breathing that speeds up beyond the needs of the cells, so that blood carbon dioxide falls too low and blood pH rises.

    This mechanism has two consequences for workplace air. In air whose oxygen has been displaced by another gas, the body’s carbon dioxide is still removed, so the drive to breathe does not increase and breathlessness does not appear as a warning. In carbon monoxide poisoning, the oxygen dissolved in the plasma can remain normal even though much of the hemoglobin no longer carries oxygen, so even the peripheral chemoreceptors are not triggered. In both situations, the body is short of oxygen without feeling suffocated.

    Altitude shows the role of partial pressure. The percentage of oxygen stays at about 21 percent, but its partial pressure falls from about 159 mm Hg at sea level to 133 mm Hg at 5,000 feet and 118 mm Hg at 8,000 feet. Hemoglobin saturation is about 67 percent at 19,000 feet, compared with about 98 percent at sea level.

    Carbon monoxide and hemoglobin

    Carbon monoxide (CO) is a colorless, odorless gas from incomplete combustion. Its affinity for hemoglobin is greater than that of oxygen, so carbon monoxide binds first and oxygen cannot occupy that heme group; the higher the percentage of carbon monoxide, the lower the oxygen saturation of hemoglobin. The gas is produced by vehicles and combustion-engine equipment, and it can cause headache, confusion, and nausea; long exposure can damage the brain or kill. Its strong binding makes poisoning hard to reverse; medical personnel treat it with pure oxygen or a high-pressure chamber. In laundries and kitchens, the usual sources are dryers, water heaters, and gas cooking equipment that are short of combustion air or whose flue gases spill back into the room, as well as generator sets and combustion engines in enclosed rooms.

    In Indonesia, Permenaker (Minister of Manpower Regulation) 5/2018 on Keselamatan dan Kesehatan Kerja Lingkungan Kerja (Occupational Safety and Health of the Work Environment) regulates threshold limit values for chemical factors. In that regulation, the threshold limit value (Indonesian nilai ambang batas, NAB) is the standard time-weighted average concentration that workers can be exposed to without causing illness or health impairment, for work not exceeding 8 hours a day or 40 hours a week. This regulation revokes Permenakertrans 13/2011, and as of November 11, 2026 it is recorded as in force. The NAB figure for carbon monoxide is read from the annex of the official text of that regulation and is not copied here. The time-weighted average is calculated from several measurement periods:

    CTWA=∑iCi ti8 hC_{\text{TWA}} = \frac{\sum_i C_i\, t_i}{8\ \text{h}}

    where CiC_i is the average concentration during period ii (ppm) and tit_i its duration (hours). The sampling method follows the regulation, and the results are interpreted by the company’s occupational safety and health (K3) expert.

    United States agencies show three kinds of limits: NIOSH recommends an average of 35 ppm for a 10-hour workday and a ceiling limit of 200 ppm, OSHA sets an average of 50 ppm, and the concentration immediately dangerous to life or health (IDLH) is 1,200 ppm. All three are US data. The lesson applies generally: a one-shift average below the limit does not mean that momentary peak concentrations are safe (Example 4).

    Irritant vapors and dust: the defenses of the airways

    Hairs and glands at the front of the nasal cavity hold back large debris, mucus traps particles, and cilia sweep them to the throat to be swallowed; cold air slows the movement of the cilia. The lining of the airways secretes lysozyme and defensins, which are antibacterial, and the carina at the branching of the trachea triggers a strong cough when a foreign object is present. The pulmonary irritant reflex protects the respiratory zone from foreign material. These innate defenses are discussed in more detail in Chapter 24.

    These defenses can be overwhelmed. In asthma, the airways become inflamed and swollen, the bronchioles narrow, and excess mucus adds to the blockage; attacks can be triggered by dust, mold, tobacco smoke, infection, or exercise and stress. In the United States about 8.2 percent of adults have asthma. Obstructive diseases, for example emphysema and asthma, hinder outflow, while restrictive diseases limit the expansion of the lungs; the ratio of forced expiratory volume in one second to forced vital capacity is below 69 percent in obstructive disease and 88 to 90 percent in restrictive disease. These figures are used by doctors when reading spirometry, not for self-assessment.

    In laundries and kitchens, irritant vapors usually come from chemicals: chlorine from bleach mixed with acid, ammonia, and concentrated cleaner vapors, whose concentrations are calculated in Chapter 11 · Chemistry and whose handling is in Chapter 6 · Safety. Linen fiber dust and mold spores are discussed in Chapter 10 and Chapter 9. Coughing, a stinging sensation, and watering eyes are signs that the airway defenses are at work, but not every substance triggers them: carbon monoxide and oxygen-displacing gases cause no sensation at all. The absence of a stinging sensation does not prove that the air is clean.

    Oxygen-deficient air

    Dry air contains about 20.9 percent oxygen. Its concentration falls when another gas displaces it, for example nitrogen from pipe purging or carbon dioxide from beverage cylinders and dry ice in a cold store, or when the oxygen is used up by rusting and decay in a closed pit. If a volume VgV_g of oxygen-free gas mixes evenly into a space containing a volume VV of air,

    xO2=20.9 %×VV+Vgx_{\text{O}_2} = 20.9\ \% \times \frac{V}{V + V_g}

    Near the source, or at floor level for gases heavier than air, the concentration is lower than this formula gives, as explained in Chapter 11 · Chemistry and Chapter 11 · Safety.

    In the United States, the OSHA confined space rule defines an oxygen-deficient atmosphere as air with less than 19.5 percent oxygen by volume and an oxygen-enriched atmosphere as above 23.5 percent by volume. That 19.5 percent figure is the limit for calling the air hazardous, not a guarantee that air above it is safe; in Indonesia the accepted concentration follows the regulations and procedures discussed in Chapter 11 · Safety.

    From the body’s side, oxygen deficiency lowers the partial pressure of alveolar oxygen as at high altitude, but instantly, without time to adapt, and without breathlessness. Chapter 11 · Safety notes that a brain short of oxygen can be damaged within a few minutes and that many confined space victims are rescuers who went down without respiratory protection. A filter mask does not add oxygen; in oxygen-deficient air only respiratory protection with its own air supply helps, and even then only for trained people according to Chapter 5 · Safety and Chapter 11 · Safety.

    Worked example

    The figures in the examples below are practice figures unless their origin is stated.

    Example 1: oxygen in outside air and in the airways. At sea level, PO2=0.209×760=158.8P_{\text{O}_2} = 0.209 \times 760 = 158.8 mm Hg, the same as the table. After the air is humidified, water vapor takes 47 mm Hg, so PO2=0.209×(760−47)=0.209×713=149.0P_{\text{O}_2} = 0.209 \times (760 - 47) = 0.209 \times 713 = 149.0 mm Hg, about 150 mm Hg. In the alveoli only about 104 mm Hg remains because the fresh air mixes with residual air and the blood keeps taking up oxygen.

    Example 2: deep or shallow breathing. A worker breathes 12 times per minute with a tidal volume of 0.50 L, and the dead space is assumed to be 0.15 L. Minute ventilation is 12×0.50=6.012 \times 0.50 = 6.0 L/min and alveolar ventilation 12×(0.50−0.15)=4.212 \times (0.50 - 0.15) = 4.2 L/min. If the worker breathes 24 times per minute with 0.25 L, minute ventilation stays at 24×0.25=6.024 \times 0.25 = 6.0 L/min, but alveolar ventilation is only 24×(0.25−0.15)=2.424 \times (0.25 - 0.15) = 2.4 L/min, about 57 percent of the original.

    Example 3: inert gas in a cold store. A 12 m³ cold store takes in 1.5 m³ of oxygen-free inert gas that mixes evenly. The oxygen concentration becomes 20.9×12/13.5=18.620.9 \times 12/13.5 = 18.6 percent, below the 19.5 percent in the OSHA definition. Its partial pressure is 0.186×760=1410.186 \times 760 = 141 mm Hg, between sea level (159 mm Hg) and 5,000 feet (133 mm Hg). The change cannot be smelled and causes no breathlessness, and at floor level the concentration can be lower. If the displacing gas is carbon dioxide, the gas itself is already hazardous at concentrations of a few percent, as in Chapter 11 · Chemistry.

    Example 4: time-weighted average of carbon monoxide. An operator’s personal detector records 40 ppm for 2 hours, 10 ppm for 3 hours, and 0 ppm for 3 hours. CTWA=(40×2+10×3+0×3)/8=110/8=13.75C_{\text{TWA}} = (40 \times 2 + 10 \times 3 + 0 \times 3)/8 = 110/8 = 13.75 ppm, or with the conversion formula of Chapter 11 · Chemistry, 13.75×28.01/24.0=16.013.75 \times 28.01/24.0 = 16.0 mg/m³. This figure is compared with the NAB in the annex of the regulation by the company’s K3 expert. If the detector briefly read 250 ppm near the exhaust duct joint, that figure is above the NIOSH ceiling limit of 200 ppm even though the shift average looks small, so the source is still shut down.

    Example 5: oxygen sites taken over by carbon monoxide. One red blood cell can contain about 300 million hemoglobin molecules, each with 4 heme groups, so 300×106×4=1.2×109300 \times 10^{6} \times 4 = 1.2 \times 10^{9} oxygen sites are available. If 20 percent of the heme groups are occupied by carbon monoxide, 0.80×1.2×109=9.6×1080.80 \times 1.2 \times 10^{9} = 9.6 \times 10^{8} sites remain. If the original oxygen saturation was 98 percent, the highest possible oxygen saturation is now 0.98×0.80=78.40.98 \times 0.80 = 78.4 percent. The oxygen dissolved in the plasma hardly changes, so the peripheral chemoreceptors are not triggered and breathing does not feel heavy.

    Example 6: the decision in the opening case. Suppose the leaking flue gas carries 0.5 L/min of carbon monoxide, that is, 0.5×60/1,000=0.030.5 \times 60/1{,}000 = 0.03 m³/h, into a room with a ventilation rate of 300 m³/h. The steady-state concentration according to Chapter 11 · Chemistry is 0.03/300=1.0×10−40.03/300 = 1.0 \times 10^{-4}, that is, 100 ppm, close to the reading of 90 ppm, and as long as the dryer is running the ventilation only holds the concentration around that figure. Headache, nausea, and miscounting without breathlessness are consistent with Example 5. The decision: the dryer is switched off from the control panel by authorized personnel, everyone goes out into fresh air, the two operators are reported to the company doctor or taken to a healthcare facility, and the room is not entered again until the detector reads normal. The rear panel is not opened in that room; the exhaust duct joint is repaired by an authorized technician according to Chapter 25 · Laundry. Whether the two operators were poisoned and what care is needed are decided by health professionals.

    Stop conditions

    Stop work, go out into fresh air, and hand over to a supervisor, the K3 officer, an authorized technician, or a health professional if:

    1. A carbon monoxide detector sounds, or two or more people in the same room complain of headache, nausea, dizziness, or confusion near gas equipment, a generator set, or a combustion engine. Everyone goes out, the source is switched off by authorized personnel, those with complaints are examined by the company doctor or a healthcare facility, and the equipment is inspected by a gas technician according to Chapter 25 · Laundry or Chapter 1 · Commercial Kitchens.
    2. Someone faints or staggers in a pit, tank, duct, or cold store. Do not go down to help without respiratory protection with its own air supply; call the rescue team and carry out the rescue plan in Chapter 11 · Safety.
    3. An enclosed space is about to be entered but its air has not been tested for oxygen, flammable gases, and toxic gases, or the detector has not been checked with test gas. The work waits for atmospheric testing and an entry permit according to Chapter 11 · Safety.
    4. Chemicals have mixed or spilled and there is a pungent smell, watering eyes, or a stinging throat. Leave the area toward clean air, report, and follow the safety data sheet according to Chapter 6 · Safety.
    5. A worker experiences breathlessness, wheezing, or repeated coughing every time they carry out a dusty or vapor-laden task. The worker is reported to the company doctor and the task is reassessed by the K3 officer.
    6. A worker is asked to wear a filter mask in air whose oxygen is low or has not been measured, or is asked to “freshen” a room with pure oxygen. Refuse, and ask for a decision from the K3 officer according to Chapter 5 · Safety and Chapter 11 · Safety.
    7. A worker is asked to judge on their own whether a coworker has been poisoned, or to give oxygen and medication without training and direction from a health professional.

    Common misinterpretations

    Guess what’s wrong first, then open the explanation.

    Common misconception

    If you are not short of breath, the air surely has enough oxygen.

    Why is it wrong?

    The drive to breathe is controlled mainly by carbon dioxide. In oxygen-deficient air and in carbon monoxide poisoning, carbon dioxide is still removed, so the body is short of oxygen without feeling suffocated.

    Common misconception

    No smell means no hazardous gas.

    Why is it wrong?

    Carbon monoxide is colorless and odorless, and oxygen-displacing gases such as nitrogen are odorless too. Their concentration is known only from a detector that has been tested.

    Common misconception

    Fast breathing means the lungs are doing more work.

    Why is it wrong?

    Fast, shallow breathing can move the same air per minute with a much smaller alveolar ventilation, as in Example 2.

    Common misconception

    A one-shift average below the NAB means there was never any danger.

    Why is it wrong?

    The NAB is a time-weighted average; momentary peak concentrations can be far above the average, such as the 250 ppm in Example 4.

    Common misconception

    A dust mask protects in a stuffy room.

    Why is it wrong?

    A filter mask holds back certain particles or vapors, but it does not add oxygen and does not hold back carbon monoxide.

    Chapter 11 · Safety applies this chapter to confined spaces and rescue, and Chapter 11 · Chemistry provides the ppm and ventilation calculations used in Example 4 and Example 6. Chapter 25 · Laundry, Chapter 1 · Commercial Kitchens, and Chapter 16 · Buildings & Facilities discuss sources of carbon monoxide in laundries and kitchens. Chapter 10 discusses bioaerosols, Chapter 24 innate defenses, Chapter 28 respiratory tract infections, Chapter 5 · Safety respiratory protection, and Chapter 6 · Safety chemicals. Chapter 37 on the heart and blood circulation continues the journey of oxygen from the lungs to the tissues.

    Exercises and worked solutions

    Try to answer first, then open the worked solution.

    1. At a place with an atmospheric pressure of 565 mm Hg, what is the partial pressure of oxygen in dry air and in humidified air?

      Check my answer
      See the worked solution

      Dry air gives 0.209×565=118.10.209 \times 565 = 118.1 mm Hg, consistent with the 118 mm Hg at 8,000 feet. After humidification, 0.209×(565−47)=108.30.209 \times (565 - 47) = 108.3 mm Hg, because the 47 mm Hg of water vapor still takes its share of the total pressure whatever the altitude.

    2. From the lung volume table, calculate the vital capacity and the total lung capacity, then explain why the residual volume is not included in the vital capacity.

      Check my answer
      See the worked solution

      Vital capacity is 1.2+0.5+3.1=4.81.2 + 0.5 + 3.1 = 4.8 L and total lung capacity 4.8+1.2=6.04.8 + 1.2 = 6.0 L. The residual volume stays in the lungs after the most forceful exhalation, so it cannot be moved in one cycle; this residual air also keeps the alveoli from collapsing.

    3. The difference in the partial pressure of carbon dioxide between the blood and the alveoli is only about 5 mm Hg, while for oxygen it is about 64 mm Hg. Why are the amounts of the two gases that cross still similar?

      Check my answer
      See the worked solution

      The solubility of carbon dioxide is about 20 times that of oxygen. The small difference multiplied by the large solubility, 5×20=1005 \times 20 = 100, is comparable to the difference of 64 for oxygen, so the amounts of the two gases that move are similar.

    4. A personal detector records carbon monoxide at 30 ppm for 4 hours and 5 ppm for 4 hours. What is the time-weighted average in ppm and in mg/m³ at 20 °C?

      Check my answer
      See the worked solution

      CTWA=(30×4+5×4)/8=140/8=17.5C_{\text{TWA}} = (30 \times 4 + 5 \times 4)/8 = 140/8 = 17.5 ppm, and 17.5×28.01/24.0=20.417.5 \times 28.01/24.0 = 20.4 mg/m³. That figure is compared with the NAB in the annex of the regulation by the K3 expert, and the source of the 30 ppm concentration in the first four hours is still tracked down.

    5. Why do carbon monoxide poisoning victims often not feel short of breath even though their tissues are short of oxygen?

      Check my answer
      See the worked solution

      The drive to breathe comes mainly from carbon dioxide, which is still removed normally, and the peripheral chemoreceptors measure only the oxygen dissolved in the plasma, which hardly changes. Hemoglobin can therefore lose many oxygen sites, as in Example 5, without any signal of breathlessness.

    6. An officer asks a technician to wear a filter mask to enter a collection pit whose oxygen has not been measured. How does the technician respond?

      Check my answer
      See the worked solution

      The technician refuses to enter and asks for atmospheric testing and an entry permit according to Chapter 11 · Safety. A filter mask does not add oxygen, while oxygen deficiency has no smell and causes no breathlessness, so the only things that can be relied on are measurement and respiratory protection with its own air supply for trained people.

    References

    External sources

    • OpenStax: Anatomy and Physiology 2eopenstax.org
    • OpenStax: Biology 2eopenstax.org
    • Peraturan Menteri Ketenagakerjaan Nomor 5 Tahun 2018 tentang Keselamatan dan Kesehatan Kerja Lingkungan Kerjajdih.kemnaker.go.id
    • 1910.146 - Permit-required confined spaces.osha.gov
    • Carbon monoxidecdc.gov

    Revision history

    DateVersionChange
    November 10, 20261First published

    How to cite

    Kurnia (2026). Respiration and workplace air: airways and alveoli, gas exchange, lung volumes, control of breathing by carbon dioxide, carbon monoxide and hemoglobin, irritant vapors and dust, and oxygen-deficient air. ARSTEMA Academy. Revised November 10, 2026. arstema.com/en/academy/konsep/pernapasan-dan-udara-kerja-saluran-napas-dan-alveolus-pertukaran-gas-volume-paru-kendali-napas-oleh-karbon-dioksida-karbon-monoksida-dan-hemoglobin-uap-iritan-dan-debu-serta-udara-miskin-oksigen

    Self-check · 3 questions

    Check your understanding before moving on

    Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.

    0/3rated

    Safety limits still apply. This quiz tests reasoning; it doesn’t authorize mixing, adjusting, dismantling, live measurement, or field action.

    1

    At a place with an atmospheric pressure of 565 mm Hg, what is the partial pressure of oxygen in dry air and in humidified air?

    2

    From the lung volume table, calculate the vital capacity and the total lung capacity, then explain why the residual volume is not included in the vital capacity.

    3

    The difference in the partial pressure of carbon dioxide between the blood and the alveoli is only about 5 mm Hg, while for oxygen it is about 64 mm Hg. Why are the amounts of the two gases that cross still similar?

    Self-assessment progress0%

    Nearby chapters