Skip to content

Search ARSTEMA

Type a chapter, term, symptom, or tool.

    Chemistry · Chapter 44Applied

    By Kurnia · Published November 15, 2026 · Version 1 · 21 min read

    Floor finish strippers

    tetrapotassium pyrophosphate and an alcohol solvent, pH 13 to 14, dilution of 25 to 50 percent, slippery floors during stripping, rinsing and pH checking, and handling and storage

    A hospital corridor has its floor finish stripped at night, one end is marked only with a cone, and a nurse slips and lands with both hands in a liquid that causes no pain. This chapter covers floor finish strippers from the side of their chemistry: tetrapotassium pyrophosphate at 5 to 10 percent and one solvent at 1 to 5 percent, pH 13 to 14, and a dilution of 25 to 50 percent according to the manufacturer’s safety data sheet for one product of this class, what that pH figure means, how a stripper softens the old finish, slippery floors during the work, machines and pads, floors suspected of containing asbestos, rinsing and neutralization, the hazards of a high-pH solution to eyes and skin, first aid, and handling and storage. No neutralizer recipe and no work sequence are given. Floor repairs, asbestos-containing floors, large spills, and treating a casualty are stated as work for other parties.

    High-risk material

    This material involves real hazards. A concept explanation doesn’t replace site procedures, competency, energy isolation, the latest SDS, or a work permit.

    Section you’re reading: Chapter opening

    The outpatient corridor of a hospital was scheduled to have its floor finish stripped at night. Two workers poured stripper solution onto the vinyl floor, spread it with a mop, and waited for the old finish to soften. One end of the corridor was closed with a chain, while the other end was marked only with a yellow cone. A nurse came in from that end, slipped on a floor that looked merely wet, and fell with both palms landing in the liquid. The nurse stood up, wiped both hands on the uniform, and went back to work because the hands did not hurt.

    That floor carried two hazards. The first was visible: a smooth floor that had been wetted on purpose. The second could not be felt. According to the manufacturer’s safety data sheet for one product of this class, the pH of the floor finish stripper is 13 to 14, and the product is used at a dilution of 25 to 50 percent. The UK Health Security Agency (UKHSA) notes that alkali injuries to the skin may be painless at first, so that treatment is delayed, and may keep progressing over several hours. Workers need to understand what is in that jerry can, what its pH figure means, why the area is closed until the floor is dry, and why rinsing decides the final result.

    Scope

    This chapter covers one class of product, namely liquid floor finish strippers with a pH of 13 to 14 that are diluted before use: contents and pH, dilution, slippery floors during the work, machines and pads, rinsing and neutralization, hazards to eyes and skin, and handling and storage. The product data come from the manufacturer’s safety data sheet for one product of this class. Other products may differ, so what applies in the workplace is the label and the safety data sheet of the product in use.

    This chapter is study material, not a work instruction. The only dilution rate written here is the dilution range on that data sheet. Contact time, the work sequence, and the type of pad are read from the product label, the machine manual, the floor manufacturer’s instructions, and the workplace procedure. No neutralizer recipe is given, and the stripping power of the product is not assessed.

    Types of floor covering, slip testing, and suspected asbestos in old tiles are in Chapter 39 · Buildings & Facilities on floors and tiles, and cleaning between two stripping jobs is in Chapter 45 on daily floor cleaners. How to check a data sheet is in Chapter 26 on reading safety data sheets for cleaning products, labels and spills are in Chapter 6 · Safety on chemicals in technician work, chemical burns are in Chapter 41 · Biology & Microbiology on the skin and chemicals, and pairs of incompatible materials are in Chapter 25 on chemical reactivity and incompatibility.

    Work outside the authority of cleaning staff and building technicians: repairing or replacing the floor covering, stripping a floor suspected of containing asbestos, handling a large spill of concentrate, and giving treatment other than first aid. Floor repairs are done by the flooring contractor appointed by the building manager, a floor suspected of containing asbestos is assessed by a competent party, large spills are handled by trained personnel or the emergency response team, and casualties are handled by a doctor or the emergency services.

    What the product contains: two listed ingredients and pH 13 to 14

    According to the manufacturer’s safety data sheet for one product of this class, the stripper is a liquid that dissolves in water, and the recommended use is stripping floor finish. Two ingredients are listed. The pH of the undiluted product is 13.0 to 14.0, its relative density is 1.02 to 1.12, and its dilution information is 25 to 50 percent. That data sheet was issued on June 23, 2024 and is valid until June 22, 2029.

    Ingredient (name on the data sheet)CAS numberConcentration (%)
    Tetrapotassium pyrophosphate7320-34-55 to 10
    Alcohols (class name only)122-99-61 to 5

    The second ingredient is written only with a class name, so its identity is read from the CAS number. The United States EPA’s list of safer chemical ingredients lists CAS number 122-99-6 as phenoxyethanol, in the preservatives class and the solvents class, and CAS number 7320-34-5 as tetrapotassium pyrophosphate, in the oxidants and oxidant stabilizers class. Both carry the yellow triangle, which marks an ingredient that meets the criteria of its class but still has some hazard profile issues.

    Tetrapotassium pyrophosphate is a potassium salt of diphosphoric acid, with four potassium ions for each diphosphate ion. Phenoxyethanol is an organic compound whose systematic name is 2-phenoxyethanol. EPA’s Safer Choice Standard, a voluntary labeling program, defines a solvent as a liquid that is able to dissolve, suspend, or extract other materials without changing those materials chemically. The product data sheet does not state the function of each ingredient.

    At 25 °C, pH and pOH add up to 14, as in Chapter 15 on advanced acids and bases, so the hydroxide ion concentration can be calculated from the pH:

    [OH−]=10−(14−pH)[\text{OH}^-] = 10^{-(14 - \text{pH})}

    with [OH−][\text{OH}^-] in mol/L. A pH of 13 means 0.1 mol/L and a pH of 14 means 1 mol/L. The Safer Choice Standard requires the pH of a product as sold to be no less than 2 and no more than 11.5, to minimize the potential for irritation or injury to skin and eyes. Against that line of 11.5, pH 13 is 1.5 units away, that is, 101.5=3210^{1.5} = 32 times in hydroxide ion concentration, and pH 14 is 2.5 units away, that is, 102.5=31610^{2.5} = 316 times.

    The two listed ingredients add up to only 6 to 15 percent of the product, and the data sheet does not explain which ingredient makes the pH that high (Example 3). For the user, what decides the handling is the pH figure, and the origin of that alkalinity is a question for the supplier.

    Floor finish and how a stripper softens it

    Floor finish in this chapter is a thin protective coating that is applied on top of the floor covering and renewed periodically, for example floor wax or an acrylic coating. The preservation guidance of the United States National Park Service (NPS) for ceramic tile floors notes that acrylic-based coating systems are commonly used in public buildings because they make maintenance easy, and that any coating requires periodic removal and renewal.

    A floor finish stripper is a product that softens the old finish so that it can be lifted off the floor. An EPA guideline from 1990 describes the sequence in general terms: before the machine is run, an emulsion of stripper in water is commonly applied to the floor with a mop to soften the wax or finish coat, and a machine is then used to remove it. The data sheet of the product in this class does not describe the mechanism, and this chapter does not assess its stripping power.

    Stripping is periodic work. NPS gives the example of tile floors in a United States government building that are stripped and recoated once a year, and warns that removing a coating too often can damage a tile floor if it is done with harsh chemicals or abrasive mechanical equipment.

    Dilution of 25 to 50 percent and the pH of the use solution

    The safety data sheet of the product in this class gives dilution information of 25 to 50 percent, and this chapter gives no other dilution rate. The data sheet does not explain how that percentage is to be read. In this chapter the figure is read as the share of product in the use solution, that is, the mixture of product and water that is actually poured onto the floor. The binding reading is the product label. For a volume VV of use solution,

    Vp=p100×V,pHuse≥pH+log⁡p100V_p = \frac{p}{100} \times V, \qquad \text{pH}_{use} \ge \text{pH} + \log\frac{p}{100}

    with VpV_p the volume of product in the same unit as VV and pp the percentage of product in the use solution. The right-hand side of the pH formula is the result for an unbuffered strong base at 25 °C. A solution whose alkalinity is held by a buffer drops less, so the calculated result is a lower bound.

    A quarter to a half of what is in the bucket is product. With that model, a use solution made from a concentrate with a pH of 13 to 14 still has a pH of 12.4 to 13.7 (Example 2), so the solution on the floor is treated the same as the contents of the jerry can. When diluting, HSE, the British occupational safety authority, asks for the concentrated liquid to be added to the water, not the water to the concentrated liquid.

    Slippery floors during stripping

    According to HSE, almost all slips happen on floors that are wet or dirty, and on a floor with a smooth surface, for example standard vinyl and glazed ceramic tiles, even a tiny amount of contamination already presents a problem. Stripping puts the floor in that state on purpose and for longer: the EPA guideline asks for the floor to be kept adequately wet while it is stripped and prohibits dry stripping. The floor stops being slippery only after the slurry of old finish has been lifted, the floor has been rinsed, and its surface is dry.

    NIOSH, the United States occupational safety and health institute, records contaminants on the floor as the leading cause of slip, trip, and fall incidents in healthcare facilities. NIOSH asks for areas to be blocked off while floors are cleaned, stripped, and waxed, with barriers or caution tape so that people do not enter, and for all signs to be removed once the floor is clean and dry so that they are not ignored.

    HSE ranks the ways of keeping people off a wet floor from the most effective: working during quiet hours, physically closing the area with barriers or locked doors while showing an alternative route, working in sections so that there is always a dry path, and last of all warning signs. A cone only warns of the hazard and does not prevent people from entering. Cleaning staff are themselves exposed to that risk, so the work sequence and slip-resistant footwear are taken into account as well.

    In stripping, a person who falls lands in a solution with a pH above 12, like the nurse in the opening case. For that reason every way into the area is closed, and the work is divided into sections so that workers do not walk on the solution (Example 4).

    Machines, pads, and floors that are not stripped carelessly

    Some old floor tiles contain asbestos, as discussed in Chapter 39 · Buildings & Facilities on floors and tiles. For floors like that, EPA issued interim guidelines in January 1990, which say:

    1. Stripping is done as infrequently as possible, for example once or twice a year or less, by trained staff.
    2. The floor is stripped while wet, and dry stripping is not done.
    3. A variable-speed machine is run at slow speed, about 175 to 190 revolutions per minute.
    4. The pad used is the least abrasive one possible.
    5. Stripping stops as soon as the old coat is removed. Overstripping can damage the floor and release asbestos fibers.

    EPA recommends that asbestos-containing floor covering in good condition be left in place, because improper removal could release high levels of asbestos. For other floors, the speed and the type of pad are read from the machine manual and the floor manufacturer’s instructions (Example 5). Old vinyl tiles and black adhesive that have not been tested are treated as suspected asbestos and are not stripped until a test result is available.

    Whether the product suits the floor material is a question for the floor manufacturer and the chemical supplier. NPS asks for every cleaning product to be tested first on a small, inconspicuous area, and notes that cleaning solutions that are too strong can weaken the mortar under the tiles.

    The data sheet of the product in this class names aluminum as an incompatible material. A strong base attacks aluminum and releases hydrogen gas, as discussed in Chapter 37 on liquid machine dishwashing detergent. Threshold strips, furniture legs, and funnels made of aluminum are therefore kept away from the solution.

    Rinsing and neutralization

    The EPA guideline asks for the floor to be thoroughly cleaned while it is still wet, after stripping and before the new finish is applied. For tile floors, NPS asks for the floor always to be rinsed thoroughly with clean water, preferably twice, and for the cleaning solution not to be left to dry on the tiles. Water evaporates, whereas the base and the dissolved old finish do not. Slurry that dries turns into a crust, and that crust becomes a high-pH solution again as soon as the floor is wet.

    Neutralization is the reaction of an acid with a base that produces a salt and water, as in Chapter 15. The safety data sheet of the product in this class does not mention a neutralizing step or a neutralizing agent. This chapter therefore gives no neutralizer recipe. If the stripper label or the label of the new finish calls for a neutralizer product, its type and dilution rate are taken from that label. What workers can check is the result: the pH of the last rinse water is measured with pH paper and compared with the pH of tap water (Example 6).

    Pouring an acid cleaner onto a floor that still holds stripper is not controlled neutralization. The data sheet names acids as materials that are incompatible with this product, and HSE gives a short rule: never mix cleaning substances. After the last rinse, the floor is left to dry completely before people are allowed through, and the barriers are removed after that.

    Eyes, skin, and first aid

    In its guidance on sodium hydroxide, UKHSA explains that alkalis damage tissue by saponifying fats and dissolving proteins and collagen. The tissue softens, so the alkali can penetrate deeper and cause full-thickness burns. The injury may be painless at first and may progress over several hours. In the eyes, alkaline solutions may penetrate and damage all layers of the eye, so the event is treated as an eye emergency. The stripper data sheet does not name the base it contains, but a pH of 13 to 14 places it under the same handling.

    HSE notes that many cleaning substances are corrosive and can cause skin and eye burns if splashed. HSE asks for the protective clothing provided always to be worn when handling cleaning substances, especially concentrates, and for eye protection suitable for splash risks, for example goggles or a visor, to be worn if there is any danger of splashing. Rubber gloves are checked for holes, tears, and thin patches. Where tap water is not available for eye irrigation, at least one liter of sterile water or sterile 0.9 percent saline in sealed disposable containers is provided.

    The type of glove material and footwear is read from the product data sheet and the maker’s table, as in Chapter 5 · Safety on personal protective equipment. If the data sheet of a product with a pH of 13 to 14 says that skin protection is not required, its content is checked in the way described in Chapter 26 and raised with the supplier.

    First aid follows the workplace procedure. The HSE guidance for chemical injuries:

    1. Skin. The first aider takes care not to become contaminated. The affected area is flooded with water for 20 minutes, and the flooding continues on the way to hospital if necessary. Contaminated clothing that is not stuck to the skin is removed.
    2. Eyes. The eye is flushed with water or sterile fluid for at least 10 minutes with the eyelids held open, and the casualty is then sent to hospital.

    If the liquid is swallowed or someone is short of breath, the emergency services are called and the product data sheet is taken to the doctor. That guidance uses water, not vinegar or any other acid.

    Handling and storage

    The manufacturer’s safety data sheet for one product of this class gives a storage temperature of -10 to 45 °C and names aluminum and acids as incompatible materials. The stripper jerry can is therefore kept away from acid bathroom cleaners and descalers, and this product is not held in or measured with aluminum containers.

    HSE gives guidance on storing and handling cleaning substances in the hospitality industry:

    • Substances are kept in their original labeled containers, and are never transferred into food or drink containers.
    • The storage place is away from heat, sunlight, foodstuffs, and members of the public, especially children, and all containers have lids.
    • Pouring from bulk containers is avoided, and solutions are carried in lidded containers, especially if floors are wet or slippery.
    • Cleaning substances are used only in well-ventilated areas.

    The slurry left from stripping holds old finish, base, and phosphate compounds. As a general rule the Safer Choice Standard does not allow phosphates in the products it certifies, because phosphorus-containing chemicals contribute to eutrophication, that is, the excessive enrichment of water bodies with nutrients. That is why the slurry and the rinse water are not disposed of into a storm drain, a ditch, or the ground. Both are disposed of through the drain designated by the workplace, and leftover product and empty containers are handled according to the label and Chapter 35 · Water & Water Treatment on B3 waste.

    Worked example

    The figures in the examples below are practice figures, unless their origin is stated. A relative density of 1.07 is used as the midpoint of the range on the data sheet, and a layer of liquid 1 mm thick over 1 m² has a volume of 1 liter.

    Example 1: product and water for one bucket. For 12 liters of use solution, the 25 percent dilution needs 0.25×12=3.00.25 \times 12 = 3.0 liters of product and 12−3.0=9.012 - 3.0 = 9.0 liters of water. The 50 percent dilution needs 0.50×12=6.00.50 \times 12 = 6.0 liters of product and 12−6.0=6.012 - 6.0 = 6.0 liters of water.

    Example 2: estimated pH of the use solution. The 25 percent dilution lowers the pH by −log⁡0.25=0.60-\log 0.25 = 0.60 and the 50 percent dilution by −log⁡0.50=0.30-\log 0.50 = 0.30. A concentrate with a pH of 13 at the most dilute rate becomes 13−0.60=12.4013 - 0.60 = 12.40, and a concentrate with a pH of 14 at the most concentrated rate becomes 14−0.30=13.7014 - 0.30 = 13.70. Against the line of 11.5, the lowest result is 12.40−11.5=0.9012.40 - 11.5 = 0.90 units away, that is, 100.90=7.910^{0.90} = 7.9 times, and the highest result is 13.70−11.5=2.2013.70 - 11.5 = 2.20 units away, that is, 102.20=15810^{2.20} = 158 times. That whole range is above 11.5.

    Example 3: the contents of one jerry can. A 5 liter jerry can holds 5×1.07=5.355 \times 1.07 = 5.35 kg of product. Its tetrapotassium pyrophosphate is 0.05×5.35=0.26750.05 \times 5.35 = 0.2675 kg to 0.10×5.35=0.5350.10 \times 5.35 = 0.535 kg, and its phenoxyethanol is 0.01×5.35=0.05350.01 \times 5.35 = 0.0535 kg to 0.05×5.35=0.26750.05 \times 5.35 = 0.2675 kg. Together they come to 5+1=65 + 1 = 6 percent to 10+5=1510 + 5 = 15 percent, so 100−15=85100 - 15 = 85 percent to 100−6=94100 - 6 = 94 percent of what is in the jerry can is not itemized.

    Example 4: dividing a corridor and how long it stays closed. A corridor measures 30 m by 2.4 m, so its area is 30×2.4=7230 \times 2.4 = 72 m². If it is worked in sections 3 m long, each section has an area of 3×2.4=7.23 \times 2.4 = 7.2 m² and there are 72/7.2=1072/7.2 = 10 sections. At 15 minutes per section, from the moment the solution is poured until the last rinse is lifted, the wet work lasts 10×15=15010 \times 15 = 150 minutes. With a drying time of 20 minutes added, the corridor is closed for 150+20=170150 + 20 = 170 minutes, almost three hours. If the whole corridor is flooded at once, the last section waits 9×15=1359 \times 15 = 135 minutes and its solution dries first.

    Example 5: speed at the edge of the pad. The edge of a pad of diameter dd that turns nn times per minute moves at v=πdn/60v = \pi d n/60. For a 0.43 m pad at 175 revolutions per minute, v=π×0.43×175/60=3.94v = \pi \times 0.43 \times 175/60 = 3.94 m/s, and at 190 revolutions per minute v=π×0.43×190/60=4.28v = \pi \times 0.43 \times 190/60 = 4.28 m/s. A high-speed machine at 1,500 revolutions per minute gives v=π×0.43×1,500/60=33.8v = \pi \times 0.43 \times 1{,}500/60 = 33.8 m/s, that is, 33.8/4.28=7.933.8/4.28 = 7.9 times faster.

    Example 6: leftover base and the number of rinses. After the slurry has been lifted, a 72 m² floor still carries a layer of solution 0.05 mm thick, that is, 72×0.05=3.672 \times 0.05 = 3.6 liters. At pH 13.70, its hydroxide ion concentration is 10−(14−13.70)=0.5010^{-(14 - 13.70)} = 0.50 mol/L, so 3.6×0.50=1.83.6 \times 0.50 = 1.8 mol of hydroxide ions are left behind. Suppose each rinse adds a layer of water 0.45 mm thick and then lifts it until 0.05 mm is left again. Each rinse dilutes that residue (0.05+0.45)/0.05=10(0.05 + 0.45)/0.05 = 10 times, so the pH drops by one unit: 13.70−1=12.7013.70 - 1 = 12.70 after the first rinse, 12.70−1=11.7012.70 - 1 = 11.70 after the second rinse, and 11.70−1=10.7011.70 - 1 = 10.70 after the third rinse. In this model two rinses do not yet bring the floor below 11.5, so the number of rinses is decided by measuring the pH of the rinse water.

    Stop conditions

    1. Concentrate or use solution gets in the eyes: stop work and flush the eye with water for at least 10 minutes while holding the eyelids open. The casualty is sent to hospital together with the product data sheet.
    2. Liquid gets on the skin or into a glove or shoe, or someone falls on a floor that is being stripped, even if it does not hurt: remove wet clothing that is not stuck to the skin and flood the skin with water for 20 minutes. Examination and treatment are done by a doctor.
    3. One of the ways into the area cannot be physically closed, or the busy hours have already started: do not pour the solution. The housekeeping supervisor and the building manager decide the schedule and the alternative route.
    4. Old vinyl or thermoplastic tiles, black adhesive under them, or a floor covering whose material has not been tested are about to be stripped: do not start. The building manager requests an asbestos assessment by a competent party according to Chapter 39 · Buildings & Facilities.
    5. On the test area or during the work, the floor covering softens, changes color, or blisters, the grout crumbles, or an aluminum part fizzes: rinse with water and stop. The flooring contractor appointed by the building manager assesses the damage.
    6. Eye protection, gloves, or suitable footwear are missing or damaged, or there is no eyewash near the area: do not open the jerry can. The supervisor provides the equipment first.
    7. An acid product or chlorine bleach is already on the floor, in the bucket, or in the machine tank, or the mixture feels hot, fizzes, or has a pungent smell: do not pour the stripper, and leave the area. The supervisor calls trained personnel or the emergency response team, and anyone short of breath is taken to the emergency services.
    8. More concentrate is spilled than the local spill kit can handle, or slurry is flowing into a drain: keep people away and hand it over to trained personnel or the emergency response team.
    9. The label is missing, the safety data sheet is missing or past its validity date, or its content does not match the pH of the product: the product is not used until the supervisor has an explanation from the supplier.

    Common misinterpretations

    Guess what’s wrong first, then open the explanation.

    Common misconception

    A stripper is a stronger floor cleaner, used the way you mop.

    Why is it wrong?

    The pH of the concentrate is 13 to 14, and a quarter to a half of its use solution is product. The area is physically closed, and skin that is contaminated is flooded with water even if it does not hurt.

    Common misconception

    It has been diluted by half, so it is harmless.

    Why is it wrong?

    According to the lower-bound model, its use solution still has a pH of 12.4 to 13.7. The solution on the floor is treated the same as the contents of the jerry can.

    Common misconception

    The floor is neutralized by pouring an acid cleaner on it.

    Why is it wrong?

    Acids are incompatible with this product, and cleaning substances are not mixed. The floor is rinsed with water, and the pH of the rinse water is measured.

    Common misconception

    The faster the machine and the coarser the pad, the cleaner the floor.

    Why is it wrong?

    The guideline for asbestos-containing floors asks for slow speed, the least abrasive pad, and stopping as soon as the old coat is removed. Overstripping damages the floor.

    Common misconception

    A yellow cone is enough.

    Why is it wrong?

    A cone only warns of the hazard. Until the floor is dry, people are kept away with barriers at every way in.

    Chapter 45 on daily floor cleaners covers the work between two stripping jobs, and Chapter 36 on strong alkaline kitchen floor cleaners covers a product with a similar pH that is used far more dilute. Chapter 39 · Buildings & Facilities on floors and tiles holds the floor types and slip testing.

    Exercises and worked solutions

    The figures in the problems are for practice.

    Try to answer first, then open the worked solution.

    1. A 16 liter bucket is to be filled with use solution at the 40 percent dilution. How many liters of product and how many liters of water are needed?

      Check my answer
      See the worked solution

      The product is 0.40×16=6.40.40 \times 16 = 6.4 liters and the water is 16−6.4=9.616 - 6.4 = 9.6 liters. That rate is used if the label does call for it, and the product is added to the water.

    2. A concentrate with a pH of 13.5 is used at the 25 percent dilution. What is the estimated lower bound of the pH of its use solution, and how many times is its hydroxide ion concentration against the line of 11.5?

      Check my answer
      See the worked solution

      The pH drops by 0.60, to 13.5−0.60=12.9013.5 - 0.60 = 12.90. That figure is 12.90−11.5=1.4012.90 - 11.5 = 1.40 units from the line of 11.5, that is, 101.40=2510^{1.40} = 25 times in hydroxide ion concentration, so the use solution is still handled with eye protection and gloves.

    3. After stripping, a worker wants to pour acid bathroom cleaner onto the floor so that the floor becomes neutral quickly. What is wrong?

      Check my answer
      See the worked solution

      Acids are incompatible with the stripper, and cleaning substances are not mixed. The floor is rinsed with clean water until the pH of the rinse water is close to the pH of tap water, and a neutralizer product is used if the label calls for it.

    4. A hotel lobby is to be stripped at ten in the morning with four cones around the area. What is changed, and by whom?

      Check my answer
      See the worked solution

      The work is moved to quiet hours and the area is closed with barriers at every way in, because cones do not prevent people from entering a floor that is wet with a high-pH solution. The schedule and the alternative route are decided by the housekeeping supervisor together with the building manager.

    5. A 20 liter jerry can holds product with a relative density of 1.07. How many kilograms does it hold, and how many kilograms of tetrapotassium pyrophosphate at most?

      Check my answer
      See the worked solution

      It holds 20×1.07=21.420 \times 1.07 = 21.4 kg, and its tetrapotassium pyrophosphate is at most 0.10×21.4=2.140.10 \times 21.4 = 2.14 kg. A jerry can that heavy is moved with a trolley, not lifted by one person.

    6. An old vinyl tile floor whose material is unknown is to be stripped dry with a machine at 1,500 revolutions per minute and a coarse pad. What is the decision?

      Check my answer
      See the worked solution

      The work is not started, because old vinyl tiles that have not been tested are treated as suspected asbestos, and high-speed dry stripping with a coarse pad goes against the guideline for floors like that. The building manager requests an assessment by a competent party first.

    References

    External sources

    • Safer Chemical Ingredients Listepa.gov
    • EPA’s Safer Choice and Design for the Environment (DfE) Standardepa.gov
    • Recommended interim guidelines for stripping wax or finish coat from asbestos-containing floorsepa.gov
    • Slip, Trip, and Fall Prevention for Healthcare Workerscdc.gov
    • Slips and trips: The importance of floor cleaninghse.gov.uk
    • Sodium hydroxide: incident managementassets.publishing.service.gov.uk
    • Safe use of cleaning substances in the hospitality industryhse.gov.uk
    • Basic advice on first aid at workhse.gov.uk
    • Preservation Briefs 40: Preserving Historic Ceramic Tile Floorsnps.gov

    Revision history

    DateVersionChange
    November 15, 20261First published

    How to cite

    Kurnia (2026). Floor finish strippers: tetrapotassium pyrophosphate and an alcohol solvent, pH 13 to 14, dilution of 25 to 50 percent, slippery floors during stripping, rinsing and pH checking, and handling and storage. ARSTEMA Academy. Revised November 15, 2026. arstema.com/en/academy/konsep/pengupas-lapisan-lantai-tetrakalium-pirofosfat-dan-pelarut-alkohol-ph-13-sampai-14-pengenceran-25-sampai-50-persen-lantai-licin-saat-pengupasan-pembilasan-dan-pemeriksaan-ph-serta-penanganan-dan-penyimpanan

    Self-check · 3 questions

    Check your understanding before moving on

    Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.

    0/3rated

    Safety limits still apply. This quiz tests reasoning; it doesn’t authorize mixing, adjusting, dismantling, live measurement, or field action.

    1

    A 16 liter bucket is to be filled with use solution at the 40 percent dilution. How many liters of product and how many liters of water are needed?

    2

    A concentrate with a pH of 13.5 is used at the 25 percent dilution. What is the estimated lower bound of the pH of its use solution, and how many times is its hydroxide ion concentration against the line of 11.5?

    3

    After stripping, a worker wants to pour acid bathroom cleaner onto the floor so that the floor becomes neutral quickly. What is wrong?

    Self-assessment progress0%

    Nearby chapters