    Commercial Kitchens · Chapter 6Applied

    By Kurnia · Published November 14, 2026 · Version 1 · 21 min read

    Commercial espresso machines

    boiler and pump, pressure and temperature, water and scale, safety valve, daily cleaning, and work limits

    During breakfast service, the safety valve of a two-group espresso machine in a hotel lobby café hisses repeatedly, the steam boiler gauge points above the green band, the water filter cartridge is overdue, and a staff member proposes opening the panel to loosen the pressurestat. This chapter covers commercial espresso machines from the building technician’s side: the arrangement of the steam boiler, brew boiler, heat exchanger, pump, and group, the two different pressures inside the machine, gauge pressure and saturation temperature, the energy stored in a hot boiler, the pressurestat, safety valve, vacuum breaker, low-water cut-off, and high-limit thermostat, periodic examination under the UK Pressure Systems Safety Regulations as explained by HSE and the machine’s position under Permenaker 4/2025 and Permenaker 37/2016, which cannot yet be confirmed, water hardness and scale, electricity in wet locations, and daily cleaning and hygiene of the milk steam wand. Opening the panel or boiler, adjusting or bypassing the pressurestat, safety valve, and temperature protection, descaling inside the boiler, and any electrical work are the work of authorized supplier technicians and authorized electricians.

    High-risk material

    This material involves real hazards. A concept explanation doesn’t replace site procedures, competency, energy isolation, the latest SDS, or a work permit.

    Section you’re reading: Chapter opening

    At seven in the morning, as the breakfast queue grows longer, the two-group espresso machine in a hotel lobby café hisses from under its panel. Steam escapes in bursts from the safety valve discharge pipe into the drip tray, and the needle of the steam boiler gauge sits above the green band. The barista switches the machine off and on again; the hissing stops briefly, then returns. The water filter cartridge is four months past its replacement date, and the milk steam wand is scaled. A kitchen staff member proposes opening the side panel to “loosen the pressurestat screw.” The technician on duty needs to know what the number on the gauge means, why the hissing is a protective device at work, and which jobs are not theirs.

    Scope

    This chapter covers commercial espresso machines permanently connected to the water supply in cafés, restaurants, and breakfast rooms of hotels or hospitals, from the building technician’s side. UK rules, as explained by HSE, are written as rules of that country. The Indonesian regulations discussed are Permenaker (Minister of Manpower Regulation) 4/2025 on steam equipment operators and Permenaker 37/2016 on K3 (occupational safety and health) for pressure vessels and storage tanks; the position of espresso machines under both cannot yet be confirmed and is discussed in the section on rules.

    Industrial boilers and their fittings are in Chapter 4 · Utilities on boilers at inspection level, steam properties and steam tables in Chapter 3 · Utilities, and steam burns and hot surfaces in Chapter 8 · Safety. Water hardness is in Chapter 4 · Laundry on water as a laundry raw material and Chapter 16 · Chemistry on solubility and scaling tendency, softeners in Chapter 21 · Water & Water Treatment, and reverse osmosis units in Chapter 11 · Water & Water Treatment to Chapter 14 · Water & Water Treatment. Thermostats and temperature protection are in Chapter 98 · Electrical & Control, RCDs in Chapter 22 · Electrical & Control, prevention of backflow from the machine into the drinking water pipe in Chapter 11 · Buildings & Facilities, kitchen sanitation in Chapter 7 · Biology & Microbiology, and energy isolation and work permits in Chapter 76 · Electrical & Control on safe work and LOTO.

    Work outside the building technician’s authority: opening the panel or boiler, removing pressurized pipes or fittings, adjusting, replacing, or bypassing the pressurestat, safety valve, vacuum breaker, low-water cut-off, and high-limit thermostat, replacing the heating element, pump, or solenoid valve, descaling inside the boiler with chemicals, and any electrical work. All of that belongs to authorized supplier technicians and authorized electricians. The building technician reads the gauges and lamps from outside, keeps records, isolates the machine at its switch, plug, or isolator and closes the water valve when there is a fault, replaces the water filter cartridge when assigned and according to the manual, supervises daily cleaning, and reports.

    Machine arrangement: boiler, heat exchanger, pump, and group

    An espresso machine is a machine that pushes hot, pressurized water through ground coffee compacted in a filter basket, and on commercial machines it also supplies steam for milk and hot water. The pressurized parts sit behind the panel, so reading the machine from outside depends on gauges and lamps.

    A steam boiler, often called the service boiler, is a metal vessel partly filled with water and heated by an electric element until it boils at a pressure above atmospheric. The steam space above the water surface supplies the steam wand and the hot water tap. The water level is held by a level probe, an electrode that sends a signal to the controller to open the fill valve when the water drops.

    Brew water is heated in one of two ways. In a heat exchanger arrangement, brew water flows through a tube that passes through the steam boiler, so the brew water is heated without mixing with the boiler water. In a dual boiler arrangement, there is a separate brew boiler that is completely filled with water and held at brewing temperature by a temperature controller. The arrangement installed is stated in the machine manual.

    The pump raises the water pressure from the building supply to brewing pressure. The group head is the mount into which the portafilter is locked, and inside it are the brew water passage and a three-way solenoid valve. The solenoid valve opens the water path to the coffee during brewing, then releases the residual pressure above the coffee into the drip tray after brewing ends.

    Two pressures inside the machine and saturation temperature

    An espresso machine has two different pressures. Steam boiler pressure is set by the temperature of the water boiling inside it, while brewing pressure from the pump exists in the brew water passage only while the pump runs. A dual gauge shows both on different scales, and the working value of each is written in the machine manual.

    A gauge shows gauge pressure, the pressure above the surrounding atmospheric pressure. Steam tables use absolute pressure:

    pabs=pgauge+patmp_{abs} = p_{gauge} + p_{atm}

    where pabsp_{abs} is absolute pressure (bar), pgaugep_{gauge} is the pressure read on the gauge (bar), and patmp_{atm} is atmospheric pressure, about 1.013 bar near sea level. Water and steam together inside the boiler are at saturation temperature, the boiling temperature of water at that absolute pressure, and its value is read from the steam table in Chapter 3 · Utilities. At a gauge pressure of 0 bar the saturation temperature is 100.0 °C, at 1 bar 120.4 °C, and at 2 bar 133.7 °C. So the steam boiler gauge also reads the temperature of the boiler water, as long as the boiler contains no air.

    Brewing pressure acts on the area of the filter basket and produces a force on the portafilter:

    F=p A,A=π4d2F = p\,A, \qquad A = \frac{\pi}{4} d^2

    where FF is force (N), pp is gauge pressure above the coffee (Pa), AA is basket area (m²), and dd is the inside diameter of the basket (m). The result is an upper bound on the force on the portafilter mount (Example 6). That is why the portafilter is not removed during brewing, and why the solenoid valve releases the residual pressure afterward.

    Energy stored in a hot boiler

    The hazard of an espresso machine boiler comes from water hotter than 100 °C held under pressure. If that pressure is released suddenly, for example because a fitting breaks or a cap is opened while hot, part of the water flashes to steam at once. The fraction of water that flashes is calculated from an energy balance:

    x=hf,1−hf,0hfg,0x = \frac{h_{f,1} - h_{f,0}}{h_{fg,0}}

    where xx is the mass fraction of water that becomes steam, hf,1h_{f,1} is the enthalpy of saturated water at boiler pressure (kJ/kg), hf,0h_{f,0} is the enthalpy of saturated water at atmospheric pressure (kJ/kg), and hfg,0h_{fg,0} is the latent heat of vaporization at atmospheric pressure (kJ/kg), all from the steam table in Chapter 3 · Utilities. The formula assumes the release is fast, with no heat exchange with the surroundings. The rest of the water, which does not flash, escapes as a spray of boiling water.

    HSE writes that failure of pressure equipment can seriously injure or kill people nearby, and that the hazards include impact from the blast of an explosion or release of the contents, impact from parts of equipment that fail, and contact with released contents such as steam. HSE guidance on the Pressure Systems Safety Regulations 2000 (PSSR) adds that the risk from steam includes its scalding effect on release, and that small steam generators present a risk from scalding rather than from stored energy. On an espresso machine both apply: the steam formed is far larger than the boiler volume (Example 3), and the spray of boiling water reaches the barista standing in front of the machine.

    Switching the machine off does not remove that hazard at once. The boiler holds water that can stay above 100 °C and under pressure while the machine cools, so HSE asks for systems to be depressurized before maintenance work. Depressurizing and waiting for the machine to cool are part of the supplier technician’s procedure, not steps for the building technician.

    Protective devices: pressurestat, safety valve, vacuum breaker, and temperature protection

    A pressurestat (pressure switch) is a switch that opens the heating element circuit when steam boiler pressure reaches the upper limit of its setting and closes it again when the pressure falls. On some machines this function is performed by an electronic controller reading a pressure or temperature sensor. The pressurestat is a control for working pressure, not the last line of protection.

    A safety valve is a spring-loaded valve that opens by itself and discharges steam when boiler pressure exceeds its set pressure, which is higher than the working pressure. It is the last line of protection if the pressurestat or controller fails. A vacuum breaker (anti-vacuum valve) lets air into the boiler as the machine cools, so the pressure inside does not fall below atmospheric and draw water or milk back through the pipes. A low-water cut-off switches off the element if the water level falls below the element, while a high-limit thermostat cuts off the element if the temperature goes far beyond its limit, and some must be reset by hand after operating (Chapter 98 · Electrical & Control).

    HSE asks for suitable protective devices to be fitted to vessels or pipework, such as safety valves and electronic devices that shut down the system when pressure, temperature, or level exceed permissible limits. Those devices must be adjusted to the correct settings, kept in good working order at all times, discharge to a safe place, and once set cannot be altered except by an authorized person. HSE also writes that a safety valve that discharges repeatedly can indicate that the system is overpressurizing or that the safety valve is not working correctly.

    That is what the hissing in the opening case means. If the gauge is above the green band and the safety valve is discharging, the pressurestat or controller is not cutting off the element in time, for example because its contacts are sticking or its connecting tube is blocked with scale. Adjusting the pressurestat does not fix that cause and can raise the working pressure beyond the design limit. Holding, tying, or plugging the safety valve removes the last line of protection. The building technician isolates the machine, keeps people away from the discharge pipe, records the gauge, and calls the supplier technician.

    Periodic examination and rules

    In the UK, PSSR applies to steam at any pressure, and to gases or mixtures at a pressure of more than 0.5 bar above atmospheric pressure. HSE writes that most pressure systems need a written scheme of examination, a document drawn up or certified by a competent person that sets out the parts to be examined, the nature of the examination, and its interval. The scheme covers all protective devices, and the system must not be operated until the scheme exists and the system has been examined. Examination under the scheme is also not a substitute for routine maintenance.

    HSE’s information sheet for catering businesses places some coffee and espresso machines in the group of steam-raising pressure plant examined according to a written scheme of examination set by a competent person. The PSSR guidance names steam boilers and pressure cookers as systems likely to need a written scheme of examination, while an office hot water urn for making tea is unlikely to. The guidance also notes that earlier UK legislation usually examined steam plant every 14 months, as a guide for the competent person, not a mandatory interval.

    In Indonesia, Permenaker 4/2025 defines steam equipment (pesawat uap) as a steam boiler and any other equipment designated by government regulation that is directly or indirectly connected to a steam boiler and intended to work under a pressure higher than ordinary air pressure. The regulation requires users of steam equipment to employ competent, licensed operators, and lists steam boilers, sterilizers, oil heaters, or other similar equipment to be designated by the Director General. Permenaker 37/2016 defines a pressure vessel as a vessel other than steam equipment that holds gas or air, and establishes the Ahli K3 (occupational safety and health expert) in steam equipment and pressure vessels.

    As of November 2026, JDIH Kemnaker (the ministry’s legal documentation and information network) records Permenaker 4/2025 and Permenaker 37/2016 as in force, and Permenaker 11/2026 revokes several articles of Permenaker 37/2016 on specialist labor inspectors without changing the definition above. Whether an espresso machine boiler counts as steam equipment that must be examined, at what interval, and whether its user must have a licensed operator cannot be confirmed from the texts that could be opened. Management puts that question to the labor inspector or a K3 expert in steam equipment and pressure vessels; the technician does not guess. Meanwhile, service records and evidence of protective device checks are kept with the machine file.

    Water and scale

    Building water carries calcium and magnesium ions expressed as hardness, usually in mg/L as calcium carbonate (Chapter 4 · Laundry and Chapter 16 · Chemistry). Water that evaporates leaves its hardness behind as scale, so scale grows fastest in the steam boiler: on the element, the level probe, the pressurestat connecting tube, the fill valve, and the steam wand nozzle.

    The mass of scale can be estimated with a mass balance:

    m=C V nm = C\,V\,n

    where mm is the mass of scale as calcium carbonate (mg), CC is feedwater hardness (mg/L), VV is the volume of water evaporated per day (L), and nn is the number of days. The formula is an upper bound, because some hardness leaves with hot water from the tap and not all deposits stick (Example 5).

    Scale on the element hinders heat transfer, scale on the level probe makes the controller misread the water level, and scale in the pressurestat tube makes the pressurestat read pressure late, as in the opening case. For that reason feedwater is treated according to the supplier’s recommendation: filters and softeners in Chapter 21 · Water & Water Treatment, or reverse osmosis units in Chapter 11 · Water & Water Treatment to Chapter 14 · Water & Water Treatment. The cartridge replacement schedule is calculated from water volume and hardness, and the installation date is recorded.

    Descaling inside the boiler requires chemicals and partial dismantling, so it is done by the supplier technician according to the manufacturer’s procedure. The connection to the drinking water pipe needs backflow prevention (Chapter 11 · Buildings & Facilities).

    Electricity in wet locations

    The boiler element’s power is written on the machine nameplate, and its current is calculated:

    I1=PV,I3=P3 VLI_1 = \frac{P}{V}, \qquad I_3 = \frac{P}{\sqrt{3}\,V_L}

    where I1I_1 is single-phase current (A), I3I_3 is the current per phase for a balanced three-phase load (A), PP is nameplate power (W), VV is single-phase voltage (V), and VLV_L is line-to-line voltage (V). A resistive element is taken to have a power factor of 1. The result is compared with the rating of the socket outlet and circuit protection recorded on the installation drawing (Example 4).

    An espresso machine works in a place that is always wet from drips, steam, and rinse water. HSE writes that the risk of electrical injury is greatest in wet surroundings, because unsuitable equipment can easily become live and can make its surroundings live. HSE also writes that RCDs for protecting people have a rated tripping current of not more than 30 mA, must never be bypassed, and when they trip indicate a fault, so the system is checked before it is used again.

    For electrical equipment in kitchens, HSE’s catering information sheet records the recommendation of the UK engineering institution: fixed installations inspected and tested every five years, while portable equipment in kitchens is given a formal visual inspection and tested every 12 months. Those are UK figures; the hotel’s schedule is set with an authorized electrician (Chapter 114 · Electrical & Control on inspection of portable electrical appliances in hotels). The machine is not sprayed or hosed, cords and plugs are checked from outside every day, and puddles near the socket outlet are reported.

    Daily cleaning and hygiene

    Daily cleaning is done by the barista or designated staff according to the supplier’s worksheet, and the building technician makes sure the worksheet exists and is followed. The steam wand is purged briefly and wiped right after every use, so milk does not dry in the nozzle. Baskets and portafilters are soaked and rinsed, the group head seat is brushed, and the drip tray and knock box are emptied and washed.

    Backflushing is cleaning of the group passage with a blind basket, a basket without holes, so that brew water returns through the solenoid valve to the drip tray. Backflushing with a cleaning agent is done only on machines whose manual allows it, with the product and dose set by the supplier. Cleaning agents are not mixed with other substances and are stored according to the safety data sheet (Chapter 7 · Biology & Microbiology on kitchen sanitation).

    The milk steam wand is a hygiene point that is easily missed. When the steam valve closes and the remaining steam in the wand condenses, the pressure in the wand falls and can draw milk from the pitcher into the nozzle. Milk left inside a warm wand becomes a place for microbes to grow, so purging and cleaning the nozzle after use is not skipped.

    Cleaning also carries heat hazards: steam from the nozzle and water from the group scald the skin (Chapter 8 · Safety), the group body and steam wand are hot to the touch, and a portafilter removed before the pressure is released sprays coffee grounds and hot water. Heat-resistant gloves and pointing the nozzle away from the body are part of the worksheet.

    Worked example

    The numbers in the examples below are practice numbers unless their origin is stated. Steam table values are taken from Chapter 3 · Utilities.

    Example 1: reading the steam boiler gauge. The machine manual states a steam boiler working pressure of 1 bar. At that pressure the absolute pressure is pabs=1+1.013=2.01p_{abs} = 1 + 1.013 = 2.01 bar, and its saturation temperature is 120.4 °C. That morning the gauge points to 2 bar, so pabs=2+1.013=3.01p_{abs} = 2 + 1.013 = 3.01 bar and the saturation temperature is 133.7 °C, which is 133.7−120.4=13.3133.7 - 120.4 = 13.3 °C hotter than normal operation. The pressurestat or controller is not cutting out in time, so the machine is isolated and the supplier technician is called.

    Example 2: warm-up time. A steam boiler holds 8 L of water, taken as 8 kg, heated from 25 °C to 120.4 °C by a 4 kW element. The heat needed is Q=8×4.19×(120.4−25)=3,197.8Q = 8 \times 4.19 \times (120.4 - 25) = 3{,}197.8 kJ, so without heat losses the shortest warm-up time is t=3,197.8/4=799t = 3{,}197.8/4 = 799 s, about 13.3 minutes. The real time is longer because the machine body is heated as well. A machine switched on 10 minutes before opening has not reached working pressure, and that does not indicate a fault.

    Example 3: steam formed if the boiler contents are released. At a gauge pressure of 1 bar hfh_f is 506 kJ/kg, and at atmospheric pressure hfh_f is 419 kJ/kg and hfgh_{fg} is 2,257 kJ/kg. The fraction that flashes is x=(506−419)/2,257=0.0385x = (506 - 419)/2{,}257 = 0.0385. Of 8 kg of water, 8×0.0385=0.3088 \times 0.0385 = 0.308 kg becomes steam at once, with a volume of about 0.308×1.673=0.5150.308 \times 1.673 = 0.515 m³ at atmospheric pressure, more than 60 times the 8 L boiler volume, and about 7.7 kg remaining escapes as boiling water.

    Example 4: element current and its circuit. A 4 kW single-phase element at 230 V draws I1=4,000/230=17.4I_1 = 4{,}000/230 = 17.4 A. That current exceeds the 16 A socket outlet and protection recorded on the café’s installation drawing, so the machine is not connected to that circuit and the finding is reported to an authorized electrician. A three-group machine with a 6 kW three-phase element at 400 V draws I3=6,000/(3×400)=8.66I_3 = 6{,}000/(\sqrt{3} \times 400) = 8.66 A per phase.

    Example 5: scale from untreated water. A café evaporates about 30 L of water per day in the steam boiler for milk and hot water, with a hardness of 120 mg/L as calcium carbonate. The upper bound for scale is m=120×30=3,600m = 120 \times 30 = 3{,}600 mg, which is 3.6 g per day, or 3.6×30=1083.6 \times 30 = 108 g in 30 days. With a cartridge that lowers hardness to 20 mg/L, the upper bound is 20×30×30=18,00020 \times 30 \times 30 = 18{,}000 mg, which is 18 g per 30 days. The overdue cartridge in the opening case means the boiler is once again receiving the full scale load.

    Example 6: force on the portafilter. The manual states a brewing pressure of 9 bar, and the basket has an inside diameter of 58 mm. Its area is A=π/4×0.0582=0.002642A = \pi/4 \times 0.058^2 = 0.002642 m², so the largest force on the portafilter mount is F=9×105×0.002642=2,378F = 9 \times 10^5 \times 0.002642 = 2{,}378 N, equivalent to the weight of about 242 kg. A portafilter twisted off while the pump runs, or when the solenoid valve fails to release the pressure, sprays coffee grounds and hot water toward the barista.

    Stop conditions

    1. The steam boiler gauge points above the working pressure in the manual or on the nameplate, or the safety valve discharges steam repeatedly: switch the machine off at its switch or isolator, keep people away from the discharge pipe, do not adjust the pressurestat, and do not hold or plug the safety valve; call the supplier technician.
    2. Steam or hot water leaks from the machine body, a fitting, or under the panel, or the machine sounds and vibrates unusually: isolate the electricity, close the water valve, keep people away, let it cool, and hand it over to the supplier technician.
    3. The work would involve opening the panel or boiler, removing pressurized pipes, replacing the element, a valve, or the pressurestat, or descaling inside the boiler: postpone it and hand it over to the authorized supplier technician; the building technician does not open the machine.
    4. The RCD or MCB of the machine circuit trips repeatedly, a cord or plug is hot or damaged, someone feels tingling, or water pools near the socket outlet: do not restore the circuit repeatedly and do not bypass the protection; hand it over to an authorized electrician.
    5. The high-limit thermostat or low-water cut-off trips repeatedly, or the controller shows a level or temperature error: do not reset it repeatedly and do not bridge the protection; hand it over to the supplier technician.
    6. Service records or evidence of protective device checks are missing, or the machine’s position under steam equipment rules is unclear: report to management so that it can be asked of the labor inspector or a K3 expert in steam equipment and pressure vessels.
    7. Someone has been scalded by steam or hot water from the machine: give burn first aid according to the hotel procedure, report the incident, and stop using the machine until the supplier technician has examined it.

    Common misinterpretations

    Guess what’s wrong first, then open the explanation.

    Common misconception

    A coffee machine is too small to be called pressure equipment.

    Why is it wrong?

    The steam boiler holds water above 100 °C under pressure, and HSE guidance names some espresso machines as steam-raising pressure plant examined under a written scheme. Small size does not remove the scalding hazard.

    Common misconception

    A safety valve that hisses often just needs tightening.

    Why is it wrong?

    Repeated discharge indicates overpressure or a faulty valve. The cause, for example the pressurestat or controller, is examined by the supplier technician, and the safety valve is never held or plugged.

    Common misconception

    A pump pressure of 9 bar means the boiler is also at 9 bar.

    Why is it wrong?

    Brewing pressure exists in the brew water passage while the pump runs, while steam boiler pressure is lower and is set by the temperature of the boiling water. The two are read on different gauges and scales.

    Common misconception

    A water filter is installed, so scale cannot form.

    Why is it wrong?

    A cartridge reaches the end of its capacity after a certain volume of water. An overdue cartridge lets the full hardness into the boiler, as calculated in Example 5.

    Common misconception

    A machine that has been switched off is safe to open.

    Why is it wrong?

    The boiler water stays hot and pressurized while the machine cools. Depressurizing and waiting for it to cool are part of the supplier technician’s procedure.

    Chapter 4 · Utilities on boilers at inspection level covers the protective devices of large boilers, and Chapter 3 · Utilities on steam properties gives the table used here. Water treatment is in Chapter 21 · Water & Water Treatment and Chapter 11 · Water & Water Treatment to Chapter 14 · Water & Water Treatment, and temperature protection in Chapter 98 · Electrical & Control. Other motorized machines in the kitchen are covered in Chapter 7 on motorized kitchen equipment.

    Exercises and worked solutions

    The numbers in the exercises are for practice.

    Try to answer first, then open the worked solution.

    1. The steam boiler gauge points to 1 bar. What are the absolute pressure and the water temperature inside the boiler, and why can steam from the nozzle heat milk quickly?

      Check my answer
      See the worked solution

      The absolute pressure is 1+1.013=2.011 + 1.013 = 2.01 bar, and according to the steam table the water in the boiler is at about 120.4 °C. Steam at that temperature releases its latent heat as it condenses in the milk, so it heats far faster than hot water at the same temperature.

    2. The machine’s safety valve discharges steam every morning at about seven, and a staff member proposes turning the valve cap to make it tighter. What does the technician answer?

      Check my answer
      See the worked solution

      Repeated discharge can indicate overpressure because the pressurestat or controller is not cutting off the element in time, or a faulty safety valve. Turning the valve cap alters a protective device that HSE says only an authorized person may alter, so the technician refuses, isolates the machine, records the gauge reading, and calls the supplier technician.

    3. A machine evaporates 20 L of water per day with a hardness of 150 mg/L as calcium carbonate. Calculate the upper bound for scale in 30 days.

      Check my answer
      See the worked solution

      The upper bound is 150×20×30=90,000150 \times 20 \times 30 = 90{,}000 mg, which is 90 g in 30 days. A figure that large explains why feedwater is treated and cartridges are replaced by water volume, rather than waiting for the machine to have problems.

    4. The nameplate of a one-group machine states a 3 kW, 230 V element. What is its current, and what does it mean if the machine is plugged into a 10 A socket outlet?

      Check my answer
      See the worked solution

      The current is 3,000/230=13.03{,}000/230 = 13.0 A, above the 10 A rating of the socket outlet. The socket outlet and its cable can overheat, so the machine is not used there and an authorized electrician specifies a suitable circuit.

    5. While cleaning the café counter, staff spray the bottom of the machine with a hose, and then the RCD trips twice in a row. What went wrong and what is the action?

      Check my answer
      See the worked solution

      The sprayed water can get into the electrical parts of the machine and make it live, and an RCD that trips indicates a fault that needs checking. The machine is isolated and not restored repeatedly, an authorized electrician and the supplier technician examine it, and the cleaning worksheet is changed so the machine is not hosed.

    6. A manager asks whether the hotel’s espresso machine must be examined under Indonesian steam equipment rules. What does the technician answer?

      Check my answer
      See the worked solution

      Permenaker 4/2025 defines steam equipment broadly, but whether an espresso machine boiler is among the equipment that must be examined and served by a licensed operator cannot be confirmed from the texts that could be opened. The technician advises management to ask the labor inspector or a K3 expert in steam equipment and pressure vessels, while keeping the supplier’s service records and evidence of protective device checks.

    References

    External sources

    • Pressure systems: A brief guide to safety (INDG261)hse.gov.uk
    • Safety of pressure systems. Pressure Systems Safety Regulations 2000. Approved Code of Practice and guidance (L122)hse.gov.uk
    • Maintenance priorities in catering (Catering Information Sheet No 12)hse.gov.uk
    • Electrical safety and you: A brief guide (INDG231)hse.gov.uk
    • Peraturan Menteri Ketenagakerjaan Nomor 4 Tahun 2025 tentang Operator Pesawat Uapjdih.kemnaker.go.id
    • Peraturan Menteri Ketenagakerjaan Nomor 37 Tahun 2016 tentang Keselamatan dan Kesehatan Kerja Bejana Tekanan dan Tangki Timbunjdih.kemnaker.go.id
    • Peraturan Menteri Ketenagakerjaan Nomor 11 Tahun 2026 tentang Tata Cara Pengawasan Ketenagakerjaanjdih.kemnaker.go.id
    • Peraturan Menteri Ketenagakerjaan Nomor 4 Tahun 2025jdih.kemnaker.go.id

    Revision history

    DateVersionChange
    November 14, 20261First published

    How to cite

    Kurnia (2026). Commercial espresso machines: boiler and pump, pressure and temperature, water and scale, safety valve, daily cleaning, and work limits. ARSTEMA Academy. Revised November 14, 2026. arstema.com/en/academy/konsep/mesin-kopi-espresso-komersial-boiler-dan-pompa-tekanan-dan-suhu-air-dan-kerak-katup-pengaman-pembersihan-harian-serta-batas-pekerjaan

    Self-check · 3 questions

    Check your understanding before moving on

    Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.

    0/3rated

    Safety limits still apply. This quiz tests reasoning; it doesn’t authorize mixing, adjusting, dismantling, live measurement, or field action.

    1

    The steam boiler gauge points to 1 bar. What are the absolute pressure and the water temperature inside the boiler, and why can steam from the nozzle heat milk quickly?

    2

    The machine’s safety valve discharges steam every morning at about seven, and a staff member proposes turning the valve cap to make it tighter. What does the technician answer?

    3

    A machine evaporates 20 L of water per day with a hardness of 150 mg/L as calcium carbonate. Calculate the upper bound for scale in 30 days.