By Kurnia · Published November 15, 2026 · Version 1 · 21 min read
Forklifts in hotel warehouses and service areas
forklift types and their batteries, battery charging, loads and center of gravity, pedestrian routes, daily checks, and operator licensing
On the night before a large conference, the receiving warehouse of a hotel is full of beverage and linen pallets, the only licensed forklift operator is on a break, and a technician without a license is asked to move an electric forklift that is blocking a door; in the same corner two batteries are charging next to a linen rack with no high-level ventilation. This chapter covers forklifts from the side of the building technician and the hotel warehouse manager: forklift types and their power sources, charging lead-acid batteries and ventilating the charging room, capacity at the load center and stability, forklift routes and pedestrians, pre-use checks and periodic inspection, and operator licensing under Permenaker 8/2020, some articles of which were revoked by Permenaker 11/2026. HSE guidance is written as data from Great Britain. This chapter is learning material, not an instruction for operating a forklift; operation is only by operators holding a K3 license, and repair is by authorized technicians.
This material involves real hazards. A concept explanation doesn’t replace site procedures, competency, energy isolation, the latest SDS, or a work permit.
On the night before a three-day conference, the receiving warehouse of a hotel takes in beverage trucks, new linen, and stage crates belonging to the event organizer. The only licensed forklift operator is on a meal break, and the electric forklift is standing in front of the warehouse emergency door with its forks raised to waist height. An event supervisor asks the duty technician to “just back it up a little,” because the key has been left on the dashboard. In a corner of the warehouse, two forklift batteries are charging next to a rack of clean linen; the only air vents are near the floor, and a housekeeping attendant cuts between the pallets to fetch linen. The technician needs to decide what they may touch, what they must stop, and whom to call.
Scope
This chapter covers forklifts in the warehouses of hotels, hospitals, and laundries from the side of the building technician and the warehouse manager. It is learning material for recognizing dangerous conditions and understanding the division of authority; it does not teach how to drive or operate a forklift, and it gives no steps for anyone without an operator license. HSE guidance is written as data from Great Britain. For Indonesia, Permenaker 8/2020 (Minister of Manpower Regulation) on K3 (occupational safety and health) for lifting and conveying equipment is used; as of November 2026 the JDIH Kemnaker database records it as in force, while Permenaker 11/2026 on labor inspection procedures revokes Article 1 point 5, Article 141 paragraph (4), and Article 173 paragraph (3) of that regulation.
Lifting loads with slings, chain hoists, jacks, and trolleys is in Chapter 9. Cell chemistry, capacity, and battery management systems for traction batteries are in Chapter 7 · Automotive & Electric Mobility, isolation of hydraulic and gravitational energy in Chapter 4, chemicals and acid splashes in Chapter 6, personal protective equipment in Chapter 5, LPG in Chapter 5 · Commercial Kitchens, and incident investigation in Chapter 12. Dock levelers, roller shutters, and vehicle restraints are in Chapter 48 · Buildings & Facilities on loading docks.
Work outside the building technician’s authority: operating a forklift without an operator K3 license; repairing, adjusting, or modifying the forklift, its brakes, chains, forks, and hydraulics; opening a battery pack; changing the charger and the electrical installation of the charging room; and inspecting and testing forklifts for regulatory purposes. All of that belongs to licensed operators, licensed lifting and conveying equipment technicians, authorized electricians, the battery supplier, and a lawful inspector. The building technician observes, keeps records, keeps routes and the charging room in order, sets up barriers, stops work when conditions are dangerous, and reports.
Forklift types and their power sources
A forklift, also called a lift truck, is a powered vehicle that lifts, carries, and lowers loads with forks on a mast. Permenaker 8/2020 classifies forklifts, reach stackers, and hand pallets as heavy equipment within the conveying equipment group. A counterbalanced truck carries the load in front of the front wheels and balances it with a counterweight at the rear. A reach truck moves the mast or forks forward into the rack in narrow aisles, and a powered pallet truck steered while walking is used for short distances.
Permenaker 8/2020 requires a forklift mast to have a stopper at the highest lifting point and a load backrest. For forks, the regulation sets a safety factor of at least 3, deflection of no more than 1/33 of the fork length, wear of no more than 10 percent, no straightening or welding of bent or broken forks, and a height difference between double forks of no more than 3 percent of the fork length; forks may also not be extended with add-on devices. These figures are read in the inspection report, not measured by the building technician.
Forklifts are powered by batteries or by combustion engines running on LPG, gasoline, or diesel. Permenaker 8/2020 prohibits combustion-engine forklifts in work areas containing explosive materials or in enclosed rooms, so an enclosed hotel warehouse uses electric forklifts. The LPG of engine-driven forklifts in the yard is handled as in Chapter 5 · Commercial Kitchens on LPG in hotel kitchens and storerooms.
On an electric forklift, the battery is part of the counterweight. HSE asks that only batteries of the size and weight specified by the forklift manufacturer are used, because the wrong weight changes stability. A much lighter lithium battery is not fitted without the forklift manufacturer’s approval.
Traction batteries and charging
Many electric warehouse forklifts use flooded lead-acid batteries; one cell is about 2 V, so a 48 V battery has 24 cells. Cells, capacity, and charging stages are in Chapter 7 · Automotive & Electric Mobility on traction batteries; what matters here is the gas. Charging batteries, including those described as maintenance free, gives off explosive hydrogen gas; if the gas collects and meets a flame or spark, the gas and the battery can explode. Mixtures of air with 4 to 75 percent hydrogen readily ignite and explode.
HSE asks that charging takes place in a designated, well-ventilated area where smoking, naked flames, and other ignition sources including mobile phones are prohibited; that electrical apparatus is kept away from the battery; and that staff wear an acid-proof apron, gloves, and eye protection. The charger is switched off before the charging leads are connected or disconnected, unless the manufacturer specifies otherwise. The area up to one meter in all directions around batteries under charge is generally treated as zone 1, an area where a flammable atmosphere is likely to be present.
Hydrogen is very light and rises to the ceiling, so ventilation openings are installed in pairs: inlet at low level and outlet at high level, preferably in two opposing exterior walls. In a room that people enter, the hydrogen concentration is kept from exceeding 0.4 percent by volume, which is 10 percent of the lower explosive limit; in an enclosure that people do not enter, 1 percent. If the air velocity through the openings is at least 0.1 m/s, the minimum area of each opening is:
where is the minimum free area of the inlet and also of the outlet (cm²), the number of cells charged at the same time, the overcharging current (A), the current at the end of charging when the cells are gassing, and the dilution factor: 10 for rooms that people enter and 4 for closed enclosures. The current is read from the charger data or obtained from the battery supplier. If natural ventilation is insufficient, mechanical ventilation is used with an alarm for hydrogen build-up or fan failure.
The origin of the formula can be checked with Faraday’s law: one ampere-hour of current that splits water in one cell produces mol of hydrogen, about 0.456 L at 25 °C. The hydrogen rate and the airflow that dilutes it to a concentration are
with and in m³/h and a volume fraction, for example 0.004. The model assumes that all overcharging current becomes gas and that the air mixes evenly; dead air pockets under the ceiling remain dangerous even when the total airflow is sufficient.
After charging, a flooded battery is left to stand for at least 20 minutes before it is topped up with distilled water to the manufacturer’s level. Changing a battery that weighs hundreds of kilograms requires a safe system of work and trained people, with lifting equipment as in Chapter 9 on lifting loads with equipment.
Loads, load center, and stability
The actual capacity of a forklift is the largest load that may be carried at a set distance from the heels of the forks to a specified height, and the figure is stated on the forklift capacity plate or capacity chart. The load center is the horizontal distance from the vertical face of the forks to the center of gravity of the load. A counterbalanced forklift tips forward about the front axle. If (mm) is the distance from the front axle to the fork face, the tipping moment of the load must be no greater than the moment allowed by the plate:
where is the load mass (kg), its load center (mm), and the plate capacity at load center . The model is static: it ignores lift height, mast tilt, acceleration, turning, and sloping floors, all of which lower the limit. A simpler version, , ignores and gives a smaller figure. Decisions are taken from the capacity plate or chart, and loads outside the chart are referred to the forklift supplier.
A counterbalanced forklift can tip forward if the load is too heavy or wrongly placed, if it travels with the load raised, if it brakes harshly with a heavy load, or if it strikes an overhead obstruction; lateral stability is upset by turning, traveling across a slope, or a wheel dropping into a pothole. Attachments such as fork extensions reduce capacity, and a new capacity plate is fitted before the attachment is used.
Permenaker 8/2020 requires the forks or the underside of the load to be at most 15 cm above the travel surface while the forklift is moving, and a forklift not in use to be placed on level ground with the brake locked and the forks resting on the floor. HSE guidance for operators adds prohibitions: do not lift a person on the forks or on a pallet on the forks, do not carry passengers unless the forklift is designed for it, do not allow people to walk under raised forks or loads, and do not turn on a slope.
Forklift routes and pedestrians
HSE asks that pedestrians are prohibited from areas where forklifts operate where possible. Where this is not possible, pedestrian activities are separated from forklift areas as far as reasonably practicable, preferably with a physical barrier, pedestrian routes and crossing places are clearly marked, warning signs are displayed, and operators are instructed to sound the horn at set locations. Reversing alarms, beacons, convex mirrors, and high-visibility vests supplement separation and do not replace it, and sharp bends and blind spots are given barriers with black and yellow stripes.
Permenaker 8/2020 requires forklift travel surfaces to be strong and level, to have marked travel areas, to have no sharp-angled bends, and to have no steep slopes that upset balance. The regulation also sets the side clearance of a travel route: at least 60 cm from the outermost side of the forklift or of the widest load for one-way traffic, and 90 cm between two forklifts or their loads for two-way traffic. When traveling, a forklift keeps at least 10 m from the rear of the vehicle in front. If the 60 cm clearance is read as applying on both sides of the route, the minimum route width is
where and are the one-way and two-way route widths (m), and , , the greatest width of the forklift or its load (m). This reading of the outer clearance is confirmed with an Ahli K3 for lifting and conveying equipment (lifting and conveying equipment safety expert) before it is used to lay out a warehouse.
Hotel service areas are rarely designed as warehouses, and forklift routes often cross housekeeping trolleys, kitchen doors, and goods lifts. HSE asks for adequate lighting where pedestrians cross, for sudden changes of lighting level to be avoided, and for forklifts not to be driven on gradients beyond the manufacturer’s maximum.
Pre-use checks and periodic inspection
Permenaker 8/2020 assigns the operator to check the condition and working capability of the forklift, its safety devices, and its equipment before operation, and gives the operator authority to stop the forklift if a safety device or equipment is not working properly or is damaged. HSE asks for a documented pre-shift check, a defect reporting system, planned maintenance, and periodic examination; the pre-shift check includes:
- Tires, wheels, and wheel nuts; pressure of pneumatic tires.
- Function test of the parking brake, service brakes, and steering.
- Battery charged and leak free, charger off, charging lead disconnected and stored, battery retention device in place.
- Function test of lifting and tilting; hydraulic leaks.
- Overhead guard, load backrest, forks without cracks at the heels, and fork locks.
- Chains: pins, bolts, elongated links, lubrication.
- Horn, lights, and mirrors.
Operators do not repair or adjust forklifts unless qualified and authorized. Keys are kept in a secure place, issued by a responsible person, and a forklift is never left with the key in place.
Beyond the daily check, Permenaker 8/2020 requires first, periodic, special, and repeat inspection and testing. Periodic inspection and testing of conveying equipment is carried out no later than 2 years after the first inspection and testing, and then once every 1 year; it covers document and visual inspection, measurement, non-destructive testing, a function test, a dynamic load test in stages up to 100 percent of the safe working load, and a static load test of at least 110 percent of the safe working load. Special inspection and testing is carried out after a work accident, fire, or explosion.
Article 173 paragraph (3), which named who carries out inspection and testing, was revoked by Permenaker 11/2026, which now governs testing of compliance with K3 norms by labor inspectors and K3 testers. Who the lawful inspector is for a given forklift is therefore asked of the local labor inspection office. For comparison, HSE requires the lifting parts of a forklift to be thoroughly examined by a competent person at least every 12 months.
Operator licensing under Permenaker 8/2020
Permenaker 8/2020 provides that lifting and conveying equipment is operated by an operator qualified for its type and capacity, and that an operator’s authority is proven by the K3 license (Lisensi K3), the authority card for working as a technician, operator, or rigger for lifting and conveying equipment. Forklift operators are classified as class II and class I. The annex on operator qualifications places forklifts, lift trucks, reach stackers, telehandlers, and hand lifts up to 15 tons in class II, and above 15 tons in class I.
The requirements for a class II forklift operator are at least junior secondary education, at least 1 year of experience assisting in the field, fitness confirmed by a doctor, a minimum age of 19 years, a competency certificate, and a K3 license. Class I requires at least senior secondary education, 2 years of experience, and a minimum age of 20 years, with the other requirements the same. The K3 license is applied for by the management or the employer to the Director General, is valid for 5 years and can be extended for the same period, and the extension application is submitted no later than 30 days before it expires.
Two provisions are often missed in hotels. A K3 license is valid only while its holder works for the company that applied for it, and an operator who changes employer needs the license changed on the application of the new company. The management or the employer is also prohibited from employing operators and technicians without a K3 license, and must check the operators’ work logbooks once every 3 months.
For comparison, HSE asks for basic training, specific job training, and familiarization at the workplace, followed by written authorization from the employer that names the type of forklift. HSE also notes that being able to drive a car does not remove the need for forklift training, because the controls and stability are very different. The conclusion is the same in both countries: a key left in a forklift is not permission to use it.
Worked example
The figures in the examples below are practice figures unless their origin is stated.
Example 1: a long crate and the capacity plate. The forklift plate states 1,500 kg at a 500 mm load center, and the distance from the front axle to the fork face is 400 mm. A stage crate has a mass of 1,200 kg with its center of gravity 700 mm from the fork face. The moment model gives kg, so the crate is only kg below the model limit, about 2 percent. The simple model gives kg, so the crate exceeds the limit. The two models disagree and neither includes lift height, so the crate is not lifted until the capacity chart or the forklift supplier gives an answer.
Example 2: route width and following distance. A linen pallet 1.2 m wide is wider than the 1.1 m forklift, so m. With the two-sided reading, a one-way route needs m, while the warehouse aisle between racks is only 2.1 m, short by m. A two-way route for two identical forklifts needs m. At 6 km/h, which is m/s, a following distance of 10 m equals s. The aisle is reported for re-layout after assessment by an Ahli K3.
Example 3: vent area for the charging room. Two 48 V batteries of 24 cells each are charged at the same time, so . The charger data give an overcharging current of 12 A, and people enter the room, so . The minimum area of each opening is cm². The grille near the floor measures 40 cm by 45 cm, which is 1,800 cm² gross, and with a free area of 60 percent gives only cm². There is no high-level opening at all, as in the opening case. The room does not meet the HSE formula and is reported to the designer and an authorized electrician.
Example 4: hydrogen rate and airflow. For Example 3, the hydrogen rate is m³/h. To keep the concentration from exceeding 0.4 percent, the airflow is m³/h. An opening of 1,728 cm² with air at 0.1 m/s passes m³/h. The two figures differ by about times, close enough to show that the vent area formula is a hydrogen dilution formula. The airflow of an exhaust fan is still set by the designer.
Example 5: K3 license validity and operator class. The K3 license of the hotel’s forklift operator was issued on January 20, 2022 and is valid for 5 years, until January 20, 2027. The extension is submitted no later than 30 days before, which is December 21, 2026; from November 15, 2026, 36 days remain. How the 30 days are counted is confirmed with the labor office. The hotel forklift has a capacity of 1.5 tons, below 15 tons, so a class II operator is sufficient. A second operator holds a license applied for by their former labor supply company; that license is not valid for work at the hotel until it is changed on the application of the company that now employs them.
Example 6: reading the inspection report. A new forklift underwent first inspection and testing on March 10, 2025. The first periodic inspection is due no later than March 10, 2027, and then every year, which is March 10, 2028. Forks 1,150 mm long with a new thickness of 45 mm may wear down to mm; the report records 41 mm, still above the limit but with only 0.5 mm left. The height difference between the two fork tips is at most mm, and the deflection at most mm; the report records 12 mm and 9 mm. The building technician enters these dates in the schedule and asks the inspector to pay attention to fork thickness at the next inspection.
Stop conditions
- A person without an operator K3 license has been asked, or is about, to operate or move a forklift, including “just for a moment”: do not get on the forklift; secure a key left behind and hand it to the person responsible for keys, set up a barrier if the forklift is blocking an exit route, and call a licensed operator or the warehouse supervisor.
- The load exceeds the capacity plate or chart, its load center is unknown or outside the chart, the pallet is damaged, or an attachment has been fitted without a new capacity plate: the load is not lifted; the warehouse supervisor and the forklift supplier decide on another method.
- In the charging room there is a smell of acid or overflowing electrolyte, a charger cable or plug is hot, melted, or stripped, the high-level vent is blocked, or the exhaust fan has stopped: do not pull out a charging lead that is still carrying current and do not switch any switch on or off near the batteries; the designated person switches the charger off at its panel if it is safe, ignition sources are kept away, and an authorized electrician and the battery supplier are called.
- Battery acid has splashed into the eyes or onto the skin: follow the first aid instructions posted in the charging room and call the first aider or medical staff; chemical handling follows Chapter 6.
- The pre-use check finds damaged or leaking brakes, steering, horn, seat belt, chains, forks, overhead guard, or hydraulic system: the forklift is not used, it is tagged as defective, its key is held by the person responsible, and a licensed lifting and conveying equipment technician is called.
- A forklift has overturned, struck a person, a rack, or a structure, or a load has fallen: stop all forklifts in the area, call the first aider or medical staff for the casualty, do not move the forklift or the load unless the responders need it, and report to management; return to use waits for special inspection and testing.
- Pedestrians are cutting through the forklift area without separation, a pedestrian route is blocked by goods, lighting has failed, or a mirror at a bend is broken: stop forklift operation in that area until the warehouse supervisor has re-laid the routes and the lighting has been repaired.
- Someone is about to be lifted on the forks or on a pallet on the forks, or is standing under raised forks or a raised load: stop the work; work at height uses access as in Chapter 10.
- The periodic inspection and testing date has passed, or a report states that the forklift does not meet K3 requirements: report it to the management; the decision on use is taken by the management together with a lawful inspector.
Common misinterpretations
Guess what’s wrong first, then open the explanation.
Common misconception
Someone who can drive a car can move a forklift for a moment.
Why is it wrong?
The controls and stability of a forklift are very different from those of a car, and Permenaker 8/2020 requires a licensed operator of the right class, however short the distance the forklift is moved.
Common misconception
The figure on the capacity plate applies to any load.
Why is it wrong?
The figure applies at a stated load center and lift height. A load whose center of gravity is farther from the fork face lowers the limit, as with the stage crate in Example 1.
Common misconception
Maintenance-free batteries give off no gas, so they can be charged in any warehouse.
Why is it wrong?
HSE writes that charging batteries, including those described as maintenance free, gives off explosive hydrogen. A charging area needs low and high ventilation and a ban on ignition sources.
Common misconception
An operator’s K3 license is valid wherever the holder works.
Why is it wrong?
The license is valid only while the holder works for the company that applied for it, and it is valid for 5 years. The license of a newly transferred operator is checked first.
Common misconception
The operator’s daily check replaces the periodic inspection.
Why is it wrong?
The pre-use check looks for visible damage. Periodic inspection and testing includes measurement, non-destructive testing, and load tests by a lawful inspector, on its own schedule.
Links to other chapters
Chapter 9 on lifting loads with equipment explains the safe working load and center of gravity used in the capacity section, and Chapter 7 · Automotive & Electric Mobility on traction batteries explains the cells, staged charging, and battery management systems behind the charging section. Chapter 48 · Buildings & Facilities on loading docks covers the place where forklifts enter truck bodies: levelers, roller shutters, vehicle restraints, and lighting. Chapter 3 on hazard identification helps assess the risks of warehouse routes, and Chapter 12 covers investigation of forklift incidents.
Exercises and worked solutions
The figures in the exercises are for practice.
Try to answer first, then open the worked solution.
A forklift plate states 2,000 kg at 500 mm, the distance from the front axle to the fork face is 450 mm, and the load is 1,600 kg with a load center of 600 mm. What do the two models say, and what is the decision?
Check my answer
See the worked solution
The moment model gives kg and the simple model kg, both above 1,600 kg. Both models agree that the load is below the static limit, but the operator still reads the capacity chart for the lift height used, because the models ignore lift height and motion.
One 24-cell battery is charged with an overcharging current of 20 A in a room that people enter. What is the minimum area of the inlet and of the outlet?
Check my answer
See the worked solution
The area is cm² for the low opening and also for the high opening. That figure is a free area, so a grille that covers part of the opening must be larger, and the two openings are best placed in opposing exterior walls so that air flows past the battery.
A forklift is blocking an emergency door, the key has been left in it, and the operator is absent. A supervisor asks the building technician to move it. What is the technician’s answer?
Check my answer
See the worked solution
The technician refuses, because a forklift is operated only by an operator with a K3 license and the management is prohibited from employing anyone without a license for that. The technician secures the key, sets up a barrier, directs people to another exit route if needed, and calls a licensed operator or the supervisor.
An operator’s K3 license expires on March 1, 2027. When at the latest must the extension be submitted?
Check my answer
See the worked solution
Thirty days before March 1, 2027 is January 30, 2027, because February 2027 has only 28 days. The management should apply earlier, because an expired license means the operator may not be employed as an operator until the license is extended.
Why is a forklift parked with its forks resting on the floor, and why must a replacement battery match the weight specified by the manufacturer?
Check my answer
See the worked solution
Forks resting on the floor cannot drop suddenly and do not form a shin-height obstacle for pedestrians, and Permenaker 8/2020 requires this together with a locked brake on level ground. The battery is part of the counterweight, so a lighter battery reduces the balancing moment and the safe capacity of the forklift.
The first inspection and testing of a forklift took place on June 5, 2024, and as of November 15, 2026 there has been no periodic inspection. What is the finding and what does the technician do?
Check my answer
See the worked solution
The periodic inspection is due no later than 2 years after the first inspection, which is June 5, 2026, so the schedule has been missed. The technician reports it in writing to the management, and the management contacts the labor inspection office or a lawful inspector to schedule the inspection and decide on interim use.
References
External sources
- Rider-operated lift trucks: Operator training and safe use. Approved Code of Practice and guidance L117hse.gov.uk
- Use lift trucks safely: Advice for operatorshse.gov.uk
- Using electric storage batteries safelyhse.gov.uk
- Peraturan Menteri Ketenagakerjaan Nomor 8 Tahun 2020 tentang Keselamatan dan Kesehatan Kerja Pesawat Angkat dan Angkutjdih.kemnaker.go.id
- Peraturan Menteri Ketenagakerjaan Nomor 11 Tahun 2026 tentang Tata Cara Pengawasan Ketenagakerjaanjdih.kemnaker.go.id
Revision history
| Date | Version | Change |
|---|---|---|
| November 15, 2026 | 1 | First published |
How to cite
Kurnia (2026). Forklifts in hotel warehouses and service areas: forklift types and their batteries, battery charging, loads and center of gravity, pedestrian routes, daily checks, and operator licensing. ARSTEMA Academy. Revised November 15, 2026. arstema.com/en/academy/konsep/forklift-di-gudang-dan-area-servis-hotel-jenis-forklift-dan-baterainya-pengisian-baterai-beban-dan-titik-berat-jalur-pejalan-kaki-pemeriksaan-harian-serta-izin-operator
Self-check · 3 questions
Check your understanding before moving on
Write your answer in your own words, then compare it with the worked solution from this chapter’s exercises. The system doesn’t judge open answers as right or wrong; you decide which parts you’ve understood.
Safety limits still apply. This quiz tests reasoning; it doesn’t authorize mixing, adjusting, dismantling, live measurement, or field action.
A forklift plate states 2,000 kg at 500 mm, the distance from the front axle to the fork face is 450 mm, and the load is 1,600 kg with a load center of 600 mm. What do the two models say, and what is the decision?
One 24-cell battery is charged with an overcharging current of 20 A in a room that people enter. What is the minimum area of the inlet and of the outlet?
A forklift is blocking an emergency door, the key has been left in it, and the operator is absent. A supervisor asks the building technician to move it. What is the technician’s answer?
Nearby chapters
Reading order by shelf: Safety · Chapter 14.
Reading order by shelf: Safety · Chapter 12.